Introduction

D8125 Interface for D8127POPITS Points 9-71

2nd D8125 adds Points 73-135

D8128 COctoPOPIT combines

8 POPIT Points in one module.

D8129 OctoRelay provides alarm and auxiliary relay output. (Other functions available.)

Use D1255 Command Centers and/or keyswitches to arm the D9112 by area. Each panel can have up to 8 areas.Each area can have its own account number or areas can be grouped together with a common account number. Points of protection are assigned to areas.

D9112

On-board Points 1 to 8

D9131 module connects to a parallel printer to print event log locally.

D128 module allows the

D9112 to monitor two phone lines.

Figure 1: D9112 System Configuration

Points

The Radionics D9112 Control/Communicator panel provides up to 134 separate points of protection. Point programming parameters determine the panel’s response to open and shorted conditions on the point’s sensor loop. Points are programmed individually with several options to custom-fit the protection to your installation.

Points 1 to 8 are located on the D9112 circuit board (on-board points). They are standard sensor loops. The remaining 126 off-board points are POPIT (Point of Protection Input Transponder) points. Each off-board point requires a POPIT module. D8127 POPIT modules require the D8125 POPEX module. The D8128A OctoPOPIT module combines eight POPITs in a single module and does not require the D8125 POPEX module.

 

D9112

Operation & Installation Manual

 

 

© 1993 Radionics

74-06144-000-C 2/96

Page 7

Page 7