26 Converged Enhanced Ethernet Command Reference
53-1001762-01
show line
2
DRAFT: BROCADE CONFIDENTIAL
show line
Displays line parameters.
Synopsis show line [first line number| last line number]
Operands first line number Specifies the first line number. The range of valid values is 0-31.
last line number Specifies the last line number. The range of valid values is 0-31.
Defaults If the line is not specified, it displays all VTY and console information.
Command
Modes
Privileged EXEC mode
Description Use this command to display line parameters.
Usage
Guidelines
There are no usage guidelines for this command.
Examples To display line parameters:
switch#show line 10 22
Status Type Timeout(m/s) Length
Idle console 0 10:0 24
Idle vty 10 10:0 24
Idle vty 11 10:0 24
Idle vty 12 10:0 24
Idle vty 13 10:0 24
Idle vty 14 10:0 24
Idle vty 15 10:0 24
Idle vty 16 10:0 24
Idle vty 17 10:0 24
Idle vty 18 10:0 24
Idle vty 19 10:0 24
Idle vty 20 10:0 24
Idle vty 21 10:0 24
Idle vty 22 121:1212 24
switch#show line 0
Status Type Timeout(m/s) Length
Idle console 0 10:0 24
* Active vty 0 10:0 24
See Also line vty, line console, exec-timeout