Controls, Start-Up, Operation, Service, and Troubleshooting
Contents
Contents
Safety Considerations
General
Basic Controls Usage
Unit Sizes
Unit Nominal Capacity Tons
Accessory Navigator Display Module
Mode RUN Service Temperatures
SET Inputs Outputs Configuration Time Operating Alarms
Scrolling Marquee Display Menu Structure
Test
Run Status Mode and Sub-Mode Directory
Strt
SUB-MODE Keypad Display SUB-ITEM Comment Entry Expansion
Vers
Service Test Mode and Sub-Mode Directory
SUB-MODE Keypad Display Comment Entry Expansion Test
Outs
Cmpa
Set Points Mode and Sub-Mode Directory
Temperature Mode and Sub-Mode Directory
Pressure Mode and Sub-Mode Directory
Inputs Mode and Sub-Mode Directory
Outputs Mode and Sub-Mode Directory
Configuration Mode and Sub-Mode Directory
SUB-MODE Keypad Display Comment Entry Expansion EXV
OPT1
SUB-MODE Keypad Display Comment Entry Expansion Unit
SUB-MODE Keypad Display Comment
OPT2
XXX
XXX.X ΔF
DST
Time Clock Mode and Sub-Mode Directory
Date
Operating Mode and Sub-Mode Directory
Alarms Mode and Sub-Mode Directory
Mode Item Expansion Description
Operating Modes
Carrier Comfort Network CCN Interface
Controls
Control Module Communication
CCN Communication Bus Wiring
Thermistor Designations
Status Inputs
Output Relays
Almr
AUX
CCB
CHC
A30-4962
A30-4963
A30-4964
Typical Control Box for 30RAP035-060
Typical Wiring Schematic, 30RAP018-030 Units Power Wiring
Typical Wiring Schematic, 30RAP018-030 Units Control Wiring
A30-4966
Typical Wiring Schematic, 30RAP035-060 Units Power Wiring
5283
Typical Wiring Schematic, 30RAP035-060 Units Control Wiring
A30-5284
A30-4967
A30-4968
Page
CEPL130351
Deadband Multiplier
30RAP Unit Size Control Capacity Steps Capacity %
A30-4969
Operating Envelope for R-410A Compressor
30RAP Unit Size FAN Stages
Cooling Set Point Select
A30-4970
Optional Factory-Installed Hydronic Pack
Control Methods and Cooling Set Points
Control Occupancy Cooling SET Point Select Clsp Type State
CCN
→PM1E = YES
Configuring and Operating Dual Chiller Con
Dual Chiller Configuration Master Chiller Example
Rset
SUB-MODE Keypad Entry Display Item Expansion Comments
Part
Number
Dual Chiller Configuration Slave Chiller Example
Rset Slave Complete
To 20 mA Reset
Menu Configuration of 4 to 20 mA Cooling Set Point Control
Configuring Outdoor Air and Space Temperature Reset
Configuring Return Temperature Reset
Mode Keypad SUB Display
RED LED Entry Mode
Outdoor-Air Temperature Reset
To 20-mA Demand Limiting
Configuring Demand Limit
Item Expansion Comment Entry Configuration
PRE-START-UP
System Check
30RAP Minimum Cooler Flow Maximum Cooler Flow Size
START-UP and Operation
A30-4978
Temperature Limits for Standard 30RAP Units
Operating Limitations
Operation Sequence
Unit Size 30RA
Service
Electronic Components
EXV Steps
Unit Size 30RAP EXV Steps
A30-4971
Electronic Expansion Valve Details
Compressor Replacement Refer to Fig
Unit Torque Specification
Cooler
A30-4972
Oil Charge
Check Refrigerant Feed Components
LWT
A30-4973
A30-4974
Unit Cutout CUT-IN
Factory Settings, High-Pressure Switch Fixed
Check Unit Safeties
Thermistor Well
Temp Voltage Resistance Drop
100,260
143
86K Thermistor vs Resistance DTT
Drop
A30-4975
A30-499
A30-4976
Accsy
P50 Fault History Last 8 faults P51 Software version
Mode Nominal Voltage Control Input Start Jumper
A30-4977
TB1-TB2
TB13A-TB2
Fault Codes
PID
Parameters Description Mode
Motormaster V Program Parameters for Operating Modes
Replacement Replacement Part Module
Maintenance
Replacement Modules
Troubleshooting
Advanced Scroll Temperature Protection Label
30RAP Unit Cutout CUT-IN Size
Troubleshooting
Symptoms Cause Remedy
Alarm and Alert Codes
T051
T110
T153
T197
Alert GENERATED?
CCN
CSB
EMM
Compressor Stuck on Failure Alarms
Page
Appendix a Display Tables
SUB-MODE Display Item Description Comment
View
RUN
Vers
Appendix a Display Tables
Strt
Pressures Mode and Sub-Mode Directory
SUB-MODE Display Item Description Range Comment
Cool
Head
FRZ
GEN.O
SUB-MODE Display Item Description Comment
HP.A
HP.B
EXV.A
EXV.B
Rset
Bcst
SUB-MODE Display Item Description Comment Time
Date
DST
HOL.L
HD.19
HD.30
SUB-MODE Display Item Description Comment SCH.N
SCH.L
PER.1
PER.2
PER.8
PER.6
PER.7
Hist
Crnt
Rcrn
Appendix B CCN Tables
CCN Display Tables Aunit General Unit Parameters
CCN Display Tables Circaan Circuit a Analog Parameters
Description Value Units Point Name Forcible
Appendix B CCN Tables
CCN Display Tables Circban Circuit B Analog Parameters
CCN Configuration Tables Unit Unit Configuration
CCN Configuration Tables OPTIONS1 Options 1 Configuration
Description Value Default Units Point Name
CCN Display Tables Options Unit Parameters
CCN Configuration Tables OPTIONS2 Options 2 Configuration
CCN Configuration Tables Schedovr Timed Override Setup
CCN Configuration Tables Display Marquee Display Setup
CCN Configuration Tables Mmconf Motormaster Configuration
CCN Service Tables Service
Description Value Units Point Name
Description Value Point Name
CCN Maintenance Tables Alarms
Description Version Value
CCN Maintenance Tables PM-PUMP
CCN Maintenance Tables Runtest
CCN Maintenance Tables Dualchil
Appendix C Factory Settings for Pump and Manual Starters
Setting
Appendix D Optional Bacnet Communications Wiring
Optional BACnet Communications Wiring
Appendix D Optional Bacnet Communications Wiring
Table a SW3 Protocol Switch Settings For MS/TP
Table B Baud Selection Table
DS8 DS7 DS6 DS5 DS4 DS3
Table C MS/TP Wiring Recommendations
Specification Recommmendation
AWG
CL2P
CMP
Wiring Specifications Recommended Vendors and Part Numbers
Rmcorp
LED Status
Table E LED Status Indicators
RUN LED Error LED Status
Control Mode
Table G Network Points List
108
109
Appendix E Maintenance Summary and LOG Sheets
30RAP Maintenance Interval Requirements
Weekly
Quarterly
Appendix E Maintenance Summary and LOG Sheets
30RAP Weekly Maintenance Log
PSI
30RAP Monthly Maintenance Log
Unit Section Action Entry
30RAP Seasonal Shutdown Log
113
Copyright 2010 Carrier Corporation
START-UP Checklist for 30RAP Liquid Chiller
Remove and use for Job File Project Information
II. Preliminary Equipment Check
Design Information
III. Unit Start-Up
Start and Operate Machine. Complete the Following
Dual Chiller Control Only
Mode RUN Status
Record Software Versions
Unit Configuration Settings
OPTIONS1 Options Configuration
Submode Item Expansion Display Entry
OPT1
OPTIONS2 Options Configuration
CCN CCN Network Configuration
HP.A Head Pressure Cmp. Delta Configuration
HP.B Head Pressure Cmp. Delta Configuration
EXV.A Circuit a EXV Configuration
EXV.B Circuit B EXV Configuration
MM Motormaster Configuration Settings
EXV.B
Rset Reset Configuration Settings
Slct Setpoint and Ramp Load Configuration
Setpoint
SUB-MODE Keypad Display Comment
Entry Expansion