1-58
CiscoASR 9000 Series Aggregation Services Router Hardware Installation Guide
Chapter1 Preparing for Installation
RSP and RP Port Connection Guidelines
Figure1-62 RSP/RP Management LAN Port LED Indicators
Management LAN RJ-45 Cabling
When connecting the RJ-45 port to a hub, repeater, or switch, use the straight-through cable pinout as
shown in Figure1-63.
Note To comply with the intrabuilding lightning surge requirements of Telecordia GR-1089-CORE, Issue II,
Revision01, February 1999, you must use a shielded cable when connecting to the management LAN
ports on the RSP/RP card. The shielded cable is terminated by shielded connectors on both ends, with
the cable shield material tied to both connectors.
Figure1-63 Straight-Through Cable Pinout to a Hub, Repeater or Switch
When connecting the RJ-45 port to a router, use the crossover cable pi nout as shown in Figure 1-64.
Figure1-64 Crossover Cable Pinout Between RSPs/RPs
243165
MDI-X wiringMDI wiring
1 TxD+
2 TxD–
3 RxD+
6 RxD–
1 RxD+
2 RxD–
3 TxD+
6 TxD–
H11007
PRP
1 TxD+
2 TxD–
3 RxD+
6 RxD–
1 TxD+
2 TxD–
3 RxD+
6 RxD–
75431
PRP