Chapter 5 Parameters and Defaults
Optional Feature Parameters
•DialPlan, page
•
•CallCmd, page
NPrintf
Description
Use this parameter to specify the IP address and port of a host to which all Cisco ATA debug messages are sent. The program prserv.exe, which comes bundled with the Cisco ATA software, is needed to capture the debug information.
Syntax
<HOST_IP>,<HOST_PORT>
Example
If the program prserv.exe is running on a host with IP address 192.168.2.170 and listening port 9001, set NPrintf to 192.168.2.170.9001. This causes the Cisco ATA to send all debug traces to that IP address.
Value Type
Extended IP address
Default
0
Voice Configuration Menu Access Code
81
TraceFlags
Description
Use this parameter to turn on specific trace features for diagnostic use. Bit values are as follows:
•Bits 0 to 1:
–0 (default) is for simple debug messages.
–1 is for detailed debug messages.
–2 and 3 are reserved.
•Bits
•Bit
<number of recv octets> <number of late packets>
<number of lost packets> <average network jitter in 1/8 ms>
<counts in speeding up local clock (adjustment for 10 ms each time)> <counts in slowing down local clock (adjustment for 10 ms each time)>
Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator’s Guide (SIP)
|
| |
|