Voice Configuration Menu Access Code

917

UDPTOS

Description

This parameter specifies the IP precedence (ToS bit) of UDP packets. Set the lower eight bits only, as follows:

Bits 0-1: Unused

Bit 2: Reliability bit—1=request high reliability

Bit 3: Throughput bit—1=request high throughput

Bit 4: Delay bit—1=request low delay

Bits 5-7: Specify datagram precedence. Values range from 0 (normal precedence) to 7 (network control).

Value Type

Bitmap

Default

0xB8

Voice Configuration Menu Access Code

255

SigTimer

Description

This parameter controls various timeout values. Table 5-5 on page 5-33contains bit definitions of this parameter.

Value Type

Bitmap

Default

0x01418564

Voice Configuration Menu Access Code

318