8–6Cabling a Shared SCSI Bus with a TZ885 ... ... .. ................ 8–15
8–7TZ887 DLTMiniLibrary Rear Panel ... ............................ 8–16
8–8Cabling a Shared SCSI Bus with a TZ887 ... ... .. ................ 8–17
8–9TruClusterServer Cluster with aTL892 on Two Shared SCSI
Buses ... ... .... .......................................................... 8–23
8–10 TL890 and TL892 DLTMiniLibraries on Shared SCSI Buses . 8–26
8–11 TL894 TapeLibrary Four-Bus Configuration . .. ................. 8–33
8–12 Shared SCSI Buses with TL894 in Two-BusMode . ... ... ... .. .. 8–35
8–13 TL895 TapeLibrary Internal Cabling . ............................ 8–39
8–14 TL893 Three-Bus Configuration ... .. ... ............................ 8–45
8–15 TL896 Six-Bus Configuration . ... ... ... ............................. 8–46
8–16 Shared SCSI Buses with TL896 in Three-Bus Mode . ... .. ... ... 8–48
8–17 TL891 Standalone Cluster Configuration .. .. ... ... ............... 8–57
8–18 TL881 DLTMiniLibrary Rackmount Configuration ... ... ... .. . 8–60
8–19 ESL9326D Internal Cabling ... .. ... ... ............................. 8–67
9–1Standalone SCSI Signal Converter ... ............................. 9–4
9–2SBB SCSI Signal Converter .. .. ... .. ... ............................. 9–4
9–3DS-BA35X-DA Personality Module Switches .. .. ................ 9–5
9–4BN21W-0B Y Cable .. ... .............................................. 9–7
9–5HD68 TrilinkConnector (H885-AA) . .. ............................ 9–8
9–6BA350 Internal SCSI Bus ... .. ... ... .. .............................. 9–10
9–7BA356 Internal SCSI Bus ... .. ... ... .. .............................. 9–12
9–8BA356 Jumper and TerminatorModule Identification Pins . .. 9–13
9–9BA350 and BA356 Cabled forShared SCSIBus Usage . .. ... ... 9–19
9–10 TwoBA356s Cabled for SharedSCSI Bus Usage ................ 9–21
9–11 TwoUltraSCSI BA356s Cabled for SharedSCSI Bus Usage . . 9–23
9–12 Externally TerminatedShared SCSI Bus with Mid-Bus HSZ50
RAID Array Controllers ............................................. 9–26
9–13 Externally TerminatedShared SCSI Bus withHSZ50 RAID
Array Controllers at Bus End . ... .. ... .............................. 9–27
9–14 TruCluster Server Cluster Using DS-DWZZH-03, SCSI
Adapter with TerminatorsInstalled, and HSZ50 ................ 9–30
9–15 TruClusterServer ClusterUsing KZPSA-BB SCSI Adapters,
a DS-DWZZH-05 UltraSCSI Hub, and an HSZ50 RAID Array
Controller ... ........................................................... 9–31
10–1KZPSA-BB TerminationResistors . ... ............................. 10–18
Tables2–1AlphaServer Systems Supported for Fibre Channel .. .. ... ... .. 2–4
2–2RAID Controller SCSI IDs .. ... .. ... ... ............................. 2–7
2–3Supported SCSI Cables . ............................................. 2–10
Contents xiii