______________________ Note _______________________
The KZPSA-BB can be used in any configuration in place of the
KZPBA-CB. The use of the KZPSA-BB is not mentioned in this
chapter because it is not UltraSCSI hardware, and it cannot
operate at UltraSCSI speeds.
The use of the KZPSA-BB (andthe KZPBA-CB) with external termination is
covered in Chapter 10.
Itis assumed thatwhen youstart to installthe hardware necessary tocreate
a TruClusterServer configuration, you have sufficient storage to install the
TruClusterServer software, and that you have set up any RAID storagesets.
Follow the steps in Table 42 to start the procedure for TruCluster Server
hardware installation. You cansave time by installing the Memory Channel
adapters, redundant network adapters (if applicable), and KZPBA-CB SCSI
adapters all at the same time.
Follow the directions in the referenced documentation, or the steps in
the referenced tables, returning to the appropriate table when you have
completed the steps in the referenced table.
_____________________ Caution _____________________
Static electricity can damage modules and electronic components.
We recommend using a grounded antistatic wrist strap and a
grounded work surface when handling modules.
Table42: Configuring TruCluster Server Hardware
Step Action Refer to:
1Install the Memory Channel module(s),
cables, and hub(s) (if a hub is required). Chapter 5a
2Install Ethernet or FDDI network
adapters. Users guide for the applicable
Ethernet or FDDI adapter,
and the users guide for the
applicable system
Install ATM adapters if using ATM. Chapter 7 and ATMworks 350
Adapter Installation and Service
3Install a KZPBA-CB UltraSCSI adapter
for each radially connected shared SCSI
bus in each member system.
Section 4.3.1 and Table 43
46TruClusterServer System Configuration Using UltraSCSI Hardware