2. Youwill need a DWZZA-VA signal converter for the BA350. Ensure
that the DWZZA-VAsingle-ended termination jumper, J2, is installed.
Remove the termination from the differential end by removing the five
14-pin differential terminator resistor SIPs.
3. Attach an H885-AA trilink connector to the DWZZA-VA 68-pin
high-density connector.
4. Install the DWZZA-VAin slot 0 of theBA350.
9.4.1.2 Preparing a BA356 Storage Shelf for Shared SCSIUsage
Toprepare a BA356 storage shelf forshared SCSI bususage, follow these
steps:
1. Youneed either a DWZZB-AA or DWZZB-VW signal converter.
The DWZZB-VW is more commonly used. Verifysignal converter
termination as follows:
Ensure that the DWZZB W1 and W2 jumpers are installed to enable
the single-ended termination at one end of the bus. The other endof
the BA356 single-ended SCSI bus is terminated on the personality
module.
Remove the termination from the differential side of the DWZZB by
removing the five 14-pin differential terminator resistor SIPs. The
differential SCSI bus will be terminated external to the DWZZB.
2. Attach an H885-AA trilink connector to the DWZZB 68-pin high-density
connector.
3. Set the switches on the BA356 personality module as follows:
If the BA356 is to house disks with SCSI IDs in the range of 0
through 6, set the BA356 personality module address switches
1 through 7 to off.
If the BA356 is to house disks with SCSI IDs in the range of 8
through 14, set BA356 personality module address switches 1
through 3 to on and switches 4 through 7 to off.
If you are using a DWZZB-AA do not replace the personalitymodule
until you attach the cable in the next step.
4. If you are using a DWZZB-AA signal converter,use a BN21K-01
(1-meter) or BN21L-01 (1-meter) cable to connect the single-ended side
of the DWZZB-AA to the BA356 input connector,JA1, on the personality
module. Connector JA1 is on the left side of the personality module as
you face the frontof the BA356, and is hidden from normal view. This
connection forms a single-ended bus segment that is terminated by the
DWZZB single-ended termination and theBA356 termination on the
personality module. The use of a 1-meter cable keeps the single-ended
916 ConfigurationsUsing ExternalTermination or Radial Connections to Non-UltraSCSI Devices