P00>>> show dev
.
.
.
pga0.0.0.1.0 | PGA0 | WWN | |
pgb0.0.0.2.0 | PGB0 | WWN |
•You can use the wwidmgr -show adapter command as follows:
P00>>> wwidmgr |
|
| |||
item | adapter | WWN | Cur. Topo | Next Topo | |
[ | 0] | pga0.0.0.4.1 | FABRIC | FABRIC | |
[ | 1] | pgb0.0.0.3.0 | FABRIC | FABRIC |
[9999] All of the above.
•If the operating system is installed, the worldwide name of a KGPSA adapter is also displayed in the boot messages generated when the emx driver attaches to the adapter when the adapter’s host system boots. Or, you can use the grep utility and obtain the worldwide name from the
/var/adm/messages file as follows:
#grep wwn /var/adm/messages
F/W Rev 2.20X2(1.12): wwn
F/W Rev 2.20X2(1.12): wwn
F/W Rev 2.20X2(1.12): wwn
.
.
.
Record the worldwide name of each KGPSA adapter for later use.
6.5.3Setting up the HSG80 Array Controller for Tru64 UNIX Installation
This section covers setting up the HSG80 controller for operation with Tru64 UNIX Version 5.0A and TruCluster Server Version 5.0A. For more information on installing the HSG80, see the Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Configuration Guide or Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 CLI Reference Guide.
To set up an HSG80 for TruCluster Server operation, follow these steps:
1.If not already installed, install the HSG80 controller(s) into the RA8000 or ESA12000 storage arrays.
2.If used, ensure that the external cache battery (ECB) is connected to the controller cache module(s).
3.Install the
4.Set the power verification and addressing (PVA) ID. Use PVA ID 0 for the enclosure that contains the HSG80 controller(s). Set the PVA ID to 2 and 3 on expansion enclosures (if present).