Yourstorage shelves or RAID array subsystems should be set up beforecompleting this portion of an installation.Use the steps in Table 43 to set up a KZPBA-CB for a TruCluster Servercluster that uses radial connectionto a DWZZH UltraSCSI hub.Table43: Installing the KZPBA-CB for Radial Connection to a DWZZHUltraSCSI Hub
Step Action Refer to:
1Ensure that the eight KZPBA-CB internal
terminationresistor SIPs,RM1-RM8 are installed. Section4.3.1, Figure 41,
and KZPBA-CB
PCI-to-Ultra SCSI
DifferentialHost Adapter
Users Guide
2Power down the system. Install a KZPBA-CB
PCI-to-UltraSCSI differential host adapter in
the PCI slot corresponding to the logical bus to
be used for the shared SCSI bus. Ensure that
the number of adapters are within limits for the
system, and that the placement is acceptable.
TruCluster Server
Cluster Administration,
Section 2.4.2, and
KZPBA-CB PCI-to-Ultra
SCSI Differential Host
Adapter Users Guide
3Install a BN38C cable between the KZPBA-CB
UltraSCSI host adapter and a DWZZH port.
_____________________ Notes _____________________
The maximum length of a SCSI bus segment is 25 meters, including the
bus length internal to the adapter and storage devices.
One end of the BN38C cable is 68-pin high density. The other end is
68-pin VHDCI.The DWZZH accepts the 68-pin VHDCI connector.
The number of member systems in the cluster has to be one less than
the number of DWZZH ports.
4Power up the system and use the show config
and show device console commands to display
the installed devices and information about
the KZPBA-CBs on the AlphaServer systems.
Look for QLogic ISP1020 in the show config
display and isp in the show device display to
determine which devices are KZPBA-CBs.
Section 4.3.2 and
Example 41 through
Example 44
5Use the show pk* or show isp* console
commands to determine the KZPBA-CB SCSI
bus ID, and then use the set console command
to set the SCSI bus ID.
Section 4.3.3 and
Example 45 through
Example 47
TruClusterServer System ConfigurationUsing UltraSCSIHardware 49