The previous example shows four Fibre Channel devices on this SCSI bus. The Fibre Channel adapter in question, emx0, at SCSI ID 7, is denoted by the presence of the emx0 designation.

Use the emxmgr -tcommand to display the Fibre Channel topology for the adapter. For example:

# emxmgr -t emx1

 

emx1 state information:

1

Link : connection is UP

 

Point to Point

 

Fabric attached

 

FC DID 0x210413

 

Link is SCSI bus 3 (e.g. scsi3)

 

SCSI target id 7

 

portname is 1000-0000-C921-07C4

 

nodename is 1000-0000-C921-07C4

 

N_Port at FC DID 0x210013 - SCSI tgt id 5 :

2

portname 5000-1FE1-0001-8932

 

nodename 5000-1FE1-0001-8930

 

Present, Logged in, FCP Target, FCP Logged in,

 

N_Port at FC DID 0x210113 - SCSI tgt id 1 :

2

portname 5000-1FE1-0001-8931

 

nodename 5000-1FE1-0001-8930

 

Present, Logged in, FCP Target, FCP Logged in,

 

N_Port at FC DID 0x210213 - SCSI tgt id 2 :

2

portname 5000-1FE1-0001-8941

 

nodename 5000-1FE1-0001-8940

 

Present, Logged in, FCP Target, FCP Logged in,

 

N_Port at FC DID 0x210313 - SCSI tgt id 4 :

2

portname 5000-1FE1-0001-8942

 

nodename 5000-1FE1-0001-8940

 

Present, Logged in, FCP Target, FCP Logged in,

 

N_Port at FC DID 0x210513 - SCSI tgt id 6 :

2

portname 1000-0000-C921-07F4

 

nodename 2000-0000-C921-07F4

Present, Logged in, FCP Initiator, FCP Target, FCP Logged in,

N_Port at FC DID 0xfffffc - SCSI tgt id -1 :

3

portname 20FC-0060-6900-5A1B

 

nodename 1000-0060-6900-5A1B

 

Present, Logged in, Directory Server,

 

N_Port at FC DID 0xfffffe - SCSI tgt id -1 :

3

portname 2004-0060-6900-5A1B

 

nodename 1000-0060-6900-5A1B Present, Logged in, F_PORT,

1

Status of the emx1 link. The connection is a point-to-point fabric (switch) connection, and the link is up. The adapter is on SCSI bus 3 at SCSI ID 7. Both the port name and node name of the adapter (the

6–60Using Fibre Channel Storage

Page 170
Image 170
Compaq AA-RHGWB-TE manual # emxmgr -t emx1