Table82: DS-TZ89N-VW Switch Settings (cont.)
SCSI ID SCSI ID Selection Switches
2Off On Off Off Off Off Off Off
3On On Off Off Off Off Off Off
4Off Off On Off Off Off Off Off
5On Off On Off Off Off Off Off
6Off On On Off Off Off Off Off
7On On On Off Off Off Off Off
8Off Off Off On Off Off Off Off
9On Off Off On Off Off Off Off
10 Off On Off On Off Off Off Off
11 On On Off On Off Off Off Off
12 Off Off On On Off Off Off Off
13 On Off On On Off Off Off Off
14 Off On On On Off Off Off Off
15 On On On On Off Off Off Off
aSBBtape drive SCSI ID is determined by the SBB physical slot.
8.2.2 Cabling the DS-TZ89N-VW Tape Drives
No special cabling is involved with the DS-TZ89N-VWas it is installed in
a BA356 StorageWorks enclosure. A DWZZB-VA installed in slot 0 of the
BA356 provides the connection to the shared SCSI bus.
Youmust remove the DWZZB-VW differential terminators. Ensure that
jumpers W1 and W2 are installed to enable the single-ended termination.
The BA356 jumper must be installed, and connector JB1 on the personality
module must be left open to provide termination at the other end of the
single-ended bus.
A trilink connector on the differential end of the DWZZB-VW allows
connection to the shared bus. If the BA356 containing the DS-TZ89N-VW is
on the end of the bus, install an H879-AA terminator on the trilink for that
BA356 to provide termination for the shared SCSI bus.
Figure 82 shows a TruCluster Server cluster with two shared SCSI buses.
The bottom shared bus has a BA356 with disksat SCSIIDs 1, 3, 4, and 5.
The other BA356 contains a DS-TZ89N-VW at SCSI ID 2.
Configuring a Shared SCSI Bus for Tape Drive Use 87