Figure 9–14: TruCluster Server Cluster Using DS-DWZZH-03, SCSI Adapter with Terminators Installed, and HSZ50

1

KZPSA-BB

DS-DWZZH-03

T

T1

AlphaServer

T

Member

T

System 1

 

2

1

KZPSA-BB

4

 

T

2

AlphaServer

Member

System 2

T

3

HSZ50

HSZ50

ZK-1415U-AI

Table 9–4 shows the components used to create the cluster shown in Figure 9–14.

Table 9–4: Hardware Components Used in Configuration Shown in Figure 9–14

Callout Number

Description

1

BN38C cablea b

2

H885-AA HD68 trilink connector

 

 

3

H879-AA HD68 terminator

 

 

4

BN21K or BN21L cableb

aThe maximum length of the BN38C cable on one SCSI bus segment must not exceed 25 meters.

bThe maximum combined length of the BN38C and BN21K (or BN21L) cables on the storage SCSI bus segment must not exceed 25 meters.

Figure 9–15 shows a sample configuration that uses KZPSA-BB SCSI adapters, a DS-DWZZH-05 UltraSCSI hub, and an HSZ50 RAID array controller.

9–30Configurations Using External Termination or Radial Connections to Non-UltraSCSI Devices

Page 280
Image 280
Compaq AA-RHGWB-TE manual Hardware Components Used in Configuration Shown in Figure, BN21K or BN21L cableb