Table 10–3: Installing a KZPSA-BB or KZPBA-CB for use with External Termination (cont.)

Step Action

Refer to:

7Use the show pk* or show isp* console commands to determine the status of the KZPSA-BB or KZPBA-CB console environment variables, and then use the set console command to set the KZPSA-BB bus speed to fast, termination power to on, and the KZPSA or KZPBA-CB SCSI bus ID.

Section 10.1.4.1 through Section 10.1.4.3 and Example 10–6 through Example 10–9

_____________________ Notes _____________________

Ensure that the SCSI ID that you use is distinct from all other SCSI IDs on the same shared SCSI bus. If you do not remember the other SCSI IDs, or do not have them recorded, you must determine these SCSI IDs. You will have problems if you have two or more SCSI adapters at the same SCSI ID on any one SCSI bus.

8Repeat steps 1 through 7 for any other KZPSA-BBs or KZPBA-CBs to be installed on this shared SCSI bus on other member systems.

9

Install the remaining SCSI bus hardware needed

Section 9.4

 

for storage (DWZZA(B), RAID array controllers,

 

 

storage shelves, cables, and terminators).

 

 

BA350 storage shelf.

Section 9.3.1,

 

 

Section 9.4.1.1, and

 

 

Section 9.4.2.1

 

Non-UltraSCSI BA356 storage shelf.

Section 9.3.2.1,

 

 

Section 9.4.1.2, and

 

 

Section 9.4.2.2

 

Ultra BA356 storage shelf.

Section 9.3.2.2,

 

 

Section 9.4.1.3, and

 

 

Section 9.4.2.3

 

HSZ40 or HSZ50 RAID array controller

Section 9.4.3

 

 

 

10

Install the tape device hardware and cables

Chapter 8

 

on the shared SCSI bus as follows:

 

 

TZ88

Section 8.1

 

TZ89

Section 8.2

 

Compaq 20/40 GB DLT Tape Drive

Section 8.3

 

TZ885

Section 8.4

 

TZ887

Section 8.5

 

TL891/TL892 MiniLibrary

Section 8.6

10–8Configuring Systems for External Termination or Radial Connections to Non-UltraSCSI Devices

Page 290
Image 290
Compaq AA-RHGWB-TE manual Step Action Refer to