Table103: Installing a KZPSA-BB or KZPBA-CB for use with ExternalTermination (cont.)
Step Action Refer to:
7Use the show pk* or show isp* console
commands to determine the status of the
KZPSA-BB or KZPBA-CB console environment
variables, and then use the set console
command to set the KZPSA-BB bus speed to
fast, termination power to on, and the KZPSA
or KZPBA-CB SCSI bus ID.
Section10.1.4.1 through
Section 10.1.4.3 and
Example 106 through
Example 109
_____________________ Notes _____________________
Ensurethat the SCSI ID that you use is distinct from all other SCSI IDs
on the same shared SCSI bus. If you do not remember the other SCSI
IDs, or do not have them recorded, you must determine these SCSI IDs.
Youwill have problems if you have two ormore SCSI adapters at the
same SCSI ID on any one SCSI bus.
8Repeatsteps 1 through7 for any other KZPSA-BBs
or KZPBA-CBs to be installed on this shared
SCSI bus on other member systems.
9Install the remaining SCSI bus hardware needed
for storage (DWZZA(B), RAID array controllers,
storage shelves, cables, and terminators).
Section 9.4
BA350 storage shelf. Section 9.3.1,
Section 9.4.1.1, and
Section 9.4.2.1
Non-UltraSCSI BA356 storage shelf. Section 9.3.2.1,
Section 9.4.1.2, and
Section 9.4.2.2
Ultra BA356 storage shelf. Section 9.3.2.2,
Section 9.4.1.3, and
Section 9.4.2.3
HSZ40 or HSZ50 RAID array controller Section 9.4.3
10 Install the tape device hardware and cables
on the shared SCSI bus as follows: Chapter 8
TZ88 Section 8.1
TZ89 Section 8.2
Compaq 20/40 GB DLT Tape Drive Section8.3
TZ885 Section 8.4
TZ887 Section 8.5
TL891/TL892 MiniLibrary Section 8.6
108Configuring Systems for External Termination or Radial Connections
to Non-UltraSCSI Devices