2.At the HSG80, set multiple-bus failover as follows. Note that before putting the controllers in multiple-bus failover mode, you must remove any previous failover mode:

HSG80> SET NOFAILOVER

HSG80> SET MULTIBUS_FAILOVER COPY=THIS

____________________ Note _____________________

Use the controller known to have the good configuration information.

3.Execute the SHOW CONNECTION command to determine which connections have a nonzero offset as follows:

HSG80> SHOW CONNECTION

 

 

 

 

 

Connection

 

 

 

 

 

Unit

Name

Operating system

Controller

Port

Address

Status

Offset

!NEWCON49

TRU64_UNIX

THIS

2

230813

OL this

100

 

HOST_ID=1000-0000-C920-DA01

ADAPTER_ID=1000-0000-C920-DA01

!NEWCON50

TRU64_UNIX

THIS

1

230813

OL this

0

 

HOST_ID=1000-0000-C920-DA01

ADAPTER_ID=1000-0000-C920-DA01

!NEWCON51

TRU64_UNIX

THIS

2

230913

OL this

100

 

HOST_ID=1000-0000-C920-EDEB

ADAPTER_ID=1000-0000-C920-EDEB

!NEWCON52

TRU64_UNIX

THIS

1

230913

OL this

0

 

HOST_ID=1000-0000-C920-EDEB

ADAPTER_ID=1000-0000-C920-EDEB

!NEWCON53

TRU64_UNIX

OTHER

1

230913

OL other

0

 

HOST_ID=1000-0000-C920-EDEB

ADAPTER_ID=1000-0000-C920-EDEB

!NEWCON54

TRU64_UNIX

OTHER

1

230813

OL other

0

 

HOST_ID=1000-0000-C920-DA01

ADAPTER_ID=1000-0000-C920-DA01

!NEWCON55

TRU64_UNIX

OTHER

2

230913

OL other

100

 

HOST_ID=1000-0000-C920-EDEB

ADAPTER_ID=1000-0000-C920-EDEB

!NEWCON56

TRU64_UNIX

OTHER

2

230813

OL other

100

 

HOST_ID=1000-0000-C920-DA01

ADAPTER_ID=1000-0000-C920-DA01

!NEWCON57

TRU64_UNIX

THIS

2

 

offline

100

 

HOST_ID=1000-0000-C921-09F7

ADAPTER_ID=1000-0000-C921-09F7

!NEWCON58

TRU64_UNIX

OTHER

1

 

offline

0

 

HOST_ID=1000-0000-C921-09F7

ADAPTER_ID=1000-0000-C921-09F7

!NEWCON59

TRU64_UNIX

THIS

1

 

offline

0

 

HOST_ID=1000-0000-C921-09F7

ADAPTER_ID=1000-0000-C921-09F7

!NEWCON60

TRU64_UNIX

OTHER

2

 

offline

100

 

HOST_ID=1000-0000-C921-09F7

ADAPTER_ID=1000-0000-C921-09F7

!NEWCON61

TRU64_UNIX

THIS

2

210513

OL this

100

 

HOST_ID=1000-0000-C921-086C

ADAPTER_ID=1000-0000-C921-086C

6–56Using Fibre Channel Storage

Page 166
Image 166
Compaq AA-RHGWB-TE manual HSG80 SET Nofailover HSG80 SET Multibusfailover COPY=THIS