Table 8–6: MUC Switch Functions

Switch

Function

1, 2, and 3

MUC SCSI ID if Switch 7 is downa

4

and 5

Must be down, reserved for testing

 

 

 

6

 

Default is up, disable bus reset on power up

 

 

 

7

 

Host selection: Down for SCSI, up for seriala

8

 

Must be down, reserved for testing

aFor a TruCluster Server cluster, switch 7 is down, allowing switches 1, 2, and 3 to select the MUC SCSI ID.

8.10.3Setting the MUC SCSI ID

The multi-unit controller (MUC) SCSI ID is set with switch 1, 2, and 3, as shown in Table 8–7. Note that switch 7 must be down to select the SCSI bus and enable switches 1, 2, and 3 to select the MUC SCSI ID.

Table 8–7: MUC SCSI ID Selection

MUC SCSI ID

SW1

SW2

SW3

0

Down

Down

Down

 

 

 

 

1

Up

Down

Down

 

 

 

 

2

Down

Up

Downa

3

Up

Up

Down

 

 

 

 

4

Down

Down

Up

 

 

 

 

5

Up

Down

Up

 

 

 

 

6

Down

Up

Up

 

 

 

 

7

Up

Up

Up

aThis is the default MUC SCSI ID.

8.10.4Tape Drive SCSI IDs

Each tape library arrives with default SCSI ID selections. The TL893 is shown in Table 8–8. The TL896 is shown in Table 8–9.

If you must modify the tape drive SCSI IDs, use the push-button up-down counters on the rear of the drive to change the SCSI ID.

Configuring a Shared SCSI Bus for Tape Drive Use 8–43