Error Code

Message Information

 

 

 

Action

Review the logs for fan failures. If no fan failures are

 

 

detected, check inlet temperature (if available) and reinstall

 

 

processor heat sink. If the problem persists, see Getting Help.

CPU0005

Message

CPU <number> configuration is unsupported.

 

 

LCD Message

CPU <number> configuration is unsupported. Check CPU or

 

 

BIOS revision.

 

Details

System is unable to boot or may run in a degraded state.

 

Action

Review the technical specifications for supported processor

 

 

types.

CPU0010

Message

CPU <number> is throttled.

 

 

Details

The CPU is throttled due to thermal or power conditions.

 

Action

Review system logs for power or thermal exceptions.

CPU0023

Message

CPU <number> is absent.

 

 

LCD Message

CPU <number> is absent. Check CPU.

 

Action

Verify processor installation. If present, re-seat the

 

 

processor.

CPU0204

Message

CPU <number> <name> voltage is outside of range.

 

 

LCD Message

CPU <number> <name> voltage is outside of range. Re-seat

 

 

CPU.

 

Details

Voltages outside the allowable range may damage electrical

 

 

components or may cause the system to shutdown.

 

Action

1.

Turn off the system and remove input power for one

 

 

 

 

 

minute.

 

 

2.

Ensure the processor is seated correctly.

 

 

3.

Reapply input power and turn on the system.

 

 

4.

If the issue persists, see Getting Help.

CPU0700

Message

CPU <number> initialization error detected.

 

 

LCD Message

CPU <number> initialization error detected. Power cycle

 

 

system.

 

Details

System BIOS was unable to initialize the processor.

113

Page 113
Image 113
Dell R420xr owner manual CPU0005 Message, CPU0010 Message, CPU0023 Message, CPU0204 Message, CPU0700 Message