Dell R420xr owner manual For temperatures between 40 C and 45 C, de

Models: R420xr

1 128
Download 128 pages 61.61 Kb
Page 107
Image 107

Power

Heat dissipation

2132 BTU/hr maximum (redundant, 550 W power

NOTE: Heat dissipation is calculated

supply)

 

using the power supply wattage

 

rating.

 

Voltage

100–240 V AC, autoranging, 50/60 Hz

NOTE: This system is also designed to be connected to IT power systems with a phase to phase voltage not exceeding 230 V.

Battery

Coin-cell battery

3 V CR2032 Lithium coin cell

Expanded Operating Temperature

NOTE: When operating in the expanded temperature range, system performance may be impacted.

NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported on the LCD and in the System Event Log.

< 10% of annual operating hours

5 °C to 40 °C at 5% to 85% RH with 26 °C dew

 

point.

 

NOTE: Outside the standard operating

 

temperature (10 °C to 35 °C), the system can

 

operate down to 5 °C or up to 40 °C for a

 

maximum of 10% of its annual operating

 

hours.

 

For temperatures between 35 °C and 40 °C, de-

 

rate maximum allowable dry bulb temperature by

 

1 °C per 175 m above 950 m (1 °F per 319 ft).

< 1% of annual operating hours

–5 °C to 45 °C at 5% to 90% RH with 26 °C dew

 

point.

 

NOTE: Outside the standard operating

 

temperature (10 °C to 35 °C), the system can

 

operate down to –5 °C or up to 45 °C for a

 

maximum of 1% of its annual operating hours.

 

For temperatures between 40 °C and 45 °C, de-

 

rate maximum allowable dry bulb temperature by

 

1 °C per 125 m above 950 m (1 °F per 228 ft).

Expanded Operating Temperature Restrictions

• Do not perform a cold startup below 5 °C.

 

• Allow processor performance degrade.

 

Non-redundant power supplies are not

 

supported.

 

• Non Dell qualified peripheral cards and/or

 

peripheral cards are not supported.

107

Page 107
Image 107
Dell R420xr owner manual For temperatures between 40 C and 45 C, de