Dell R420xr RFM2006 Message, SEC0031 Message, SEC0033 Message, SEL0006 Message, SEL0008 Message

Models: R420xr

1 128
Download 128 pages 61.61 Kb
Page 125
Image 125

Error Code

Message Information

 

 

LCD Message

Internal Dual SD Module <name> failed. Check SD Card.

 

Details

The SD card module is installed but improperly configured or

 

 

failed to initialize.

 

Action

Reinstall the SD module and remove and reinstall SD cards.

RFM2006

Message

Internal Dual SD Module <name> is write protected.

 

 

Details

The module is write-protected. Changes may not be written

 

 

to the media.

 

Action

If unintended, remove the media and disable write

 

 

protection.

SEC0031

Message

The chassis is open while the power is on.

 

 

LCD Message

Intrusion detected. Check chassis cover.

 

Details

The chassis is open. System performance may be degraded,

 

 

and security may be compromised.

 

Action

Close the chassis. Check system logs.

SEC0033

Message

The chassis is open while the power is off.

 

 

LCD Message

Intrusion detected. Check chassis cover.

 

Details

The chassis was opened while the power was off. System

 

 

security may have been compromised.

 

Action

Close the chassis and verify hardware inventory. Check

 

 

system logs.

SEL0006

Message

All event logging is disabled.

 

 

Details

This message is displayed when all event logging has been

 

 

disabled by the user.

 

Action

If unintended, re-enable logging.

SEL0008

Message

Log is full.

 

 

Details

When the event log is full, additional events are not written

 

 

to the log. Older events may be overwritten and lost. This

 

 

message may also appear if the user disabled event logging.

 

Action

Backup and clear log.

SEL0012

Message

Could not create or initialize the system event log.

 

125

Page 125
Image 125
Dell R420xr RFM2006 Message, SEC0031 Message, SEC0033 Message, SEL0006 Message, SEL0008 Message, SEL0012 Message