Error Code

Message Information

 

MEM8000

Message

Correctable memory error logging disabled for a memory

 

 

 

device at location <location>.

 

LCD Message

SBE log disabled on <location>. Re-seat memory.

 

Details

Errors are being corrected but no longer logged.

 

Action

Review system logs for memory exceptions. Reinstall

 

 

memory at location <location>.

PCI1302

Message

A bus time-out was detected on a component at bus <bus>

 

 

 

device<device> function <func>.

 

Details

System performance may be degraded. The device has failed

 

 

to respond to a transaction.

 

Action

Cycle input power, update component drivers, if device is

 

 

removable, reinstall the device.

PCI1304

Message

An I/O channel check error was detected.

 

 

LCD Message

I/O channel check error detected. Power cycle system.

 

Action

Cycle input power, update component drivers, if device is

 

 

removable, reinstall the device.

PCI1308

Message

A PCI parity error was detected on a component at bus

 

 

 

<bus>device<device>function <func>.

 

LCD Message

PCI parity error on bus <bus> device <device> function

 

 

<func>. Power cycle system.

 

Details

System performance may be degraded, PCI device may fail

 

 

to operate, or system may fail to operate.

 

Action

Cycle input power, update component drivers, if device is

 

 

removable, reinstall the device.

PCI1320

Message

A bus fatal error was detected on a component at bus

 

 

 

<bus>device<device>function <func>.

 

LCD Message

Bus fatal error on bus <bus> device <device> function

 

 

<func>. Power cycle system.

 

Details

System performance may be degraded, or system may fail to

 

 

operate.

 

Action

Cycle input power, update component drivers, if device is

 

 

removable, reinstall the device.

118

Page 118
Image 118
Dell R420xr owner manual MEM8000 Message, PCI1302 Message, PCI1304 Message, PCI1308 Message, PCI1320 Message