Error Code

Message Information

 

PST0128

Message

No memory is detected.

 

 

LCD Message

No memory is detected. Inspect memory devices.

 

Details

System BIOS was unable to detect memory in the system.

 

Action

Re-seat the memory modules. If the issue persists, see

 

 

Getting Help.

PST0129

Message

Memory is detected, but is not configurable.

 

 

LCD Message

Memory is detected, but is not configurable. Check memory

 

 

devices.

 

Details

System BIOS detected memory, but was unable to configure

 

 

the memory for system operation.

 

Action

Compare system memory installation to supported system

 

 

memory configurations.

PSU0001

Message

Power supply <number> failed.

 

 

LCD Message

PSU <number> failed. Check PSU.

 

Action

Remove and reinstall the power supply. If the issue persists,

 

 

see Getting Help.

PSU0002

Message

A predictive failure detected on power supply <number>.

 

 

LCD Message

Predictive failure on PSU <number>. Check PSU.

 

Details

System performance and power redundancy may be

 

 

degraded or lost.

 

Action

Remove and reinstall the power supply at the next service

 

 

window. If the issue persists, see Getting Help.

PSU0003

Message

The power input for power supply <number> is lost.

 

 

LCD Message

Power input for PSU <number> is lost. Check PSU cables.

 

Details

The power supply is installed correctly but an input source is

 

 

not connected or is not functional.

 

Action

Verify the input source is attached to the power supply.

 

 

Verify the input power is within the operating requirements

 

 

for the power supply.

PSU0006

Message

Power supply <number> type mismatch.

 

120

Page 120
Image 120
Dell R420xr PST0128 Message, PST0129 Message, PSU0001 Message, PSU0002 Message, PSU0003 Message, PSU0006 Message