Error Code | Message Information |
|
PST0128 | Message | No memory is detected. |
| ||
| LCD Message | No memory is detected. Inspect memory devices. |
| Details | System BIOS was unable to detect memory in the system. |
| Action | |
|
| Getting Help. |
PST0129 | Message | Memory is detected, but is not configurable. |
| ||
| LCD Message | Memory is detected, but is not configurable. Check memory |
|
| devices. |
| Details | System BIOS detected memory, but was unable to configure |
|
| the memory for system operation. |
| Action | Compare system memory installation to supported system |
|
| memory configurations. |
PSU0001 | Message | Power supply <number> failed. |
| ||
| LCD Message | PSU <number> failed. Check PSU. |
| Action | Remove and reinstall the power supply. If the issue persists, |
|
| see Getting Help. |
PSU0002 | Message | A predictive failure detected on power supply <number>. |
| ||
| LCD Message | Predictive failure on PSU <number>. Check PSU. |
| Details | System performance and power redundancy may be |
|
| degraded or lost. |
| Action | Remove and reinstall the power supply at the next service |
|
| window. If the issue persists, see Getting Help. |
PSU0003 | Message | The power input for power supply <number> is lost. |
| ||
| LCD Message | Power input for PSU <number> is lost. Check PSU cables. |
| Details | The power supply is installed correctly but an input source is |
|
| not connected or is not functional. |
| Action | Verify the input source is attached to the power supply. |
|
| Verify the input power is within the operating requirements |
|
| for the power supply. |
PSU0006 | Message | Power supply <number> type mismatch. |
|
120