Error Code | Message Information |
|
| LCD Message | PSU wattage mismatch; PSU <number> = <value >watts |
| Details | Power supplies should be of the same input type and power |
|
| rating. |
| Action | Install matched power supplies and review this manual for |
|
| proper configuration. |
PSU1201 | Message | Power supply redundancy is lost. |
| ||
| Details | The power supply tries to operate in a degraded state. |
|
| System Performance and power redundancy may be |
|
| degraded or lost. |
| Action | Check input power. Reinstall the power supply. If the issue |
|
| persists, see Getting Help. |
PSU1204 | Message | The power supplies are not redundant. Insufficient resources |
| ||
|
| to maintain normal operations. |
| LCD Message | PSU redundancy degraded. Check PSU cables. |
| Details | The current power operational mode is |
|
| because of a power supply exception, a power supply |
|
| inventory change, or a system power inventory change. |
| Action | Check the event log for power supply failures. Review |
|
| system configuration and power consumption. |
PWR1004 | Message | The system performance degraded because power capacity |
| ||
|
| has changed. |
| Details | The system may power down or operate in a performance |
|
| degraded state. |
| Action | Check the event log for power supply failures. Review |
|
| system configuration and power consumption and upgrade |
|
| or install power supplies accordingly. |
PWR1005 | Message | The system performance degraded because the user- |
| ||
|
| defined power capacity has changed. |
| Details | The |
|
| operation. |
| Action | If unintended, review system configuration changes and |
|
| power policy. |
PWR1006 | Message | The system halted because system power exceeds capacity. |
|
123