Dell R420xr SEL1204 Message, TMP0118 Message, TMP0119 Message, TMP0120 Message, TMP0121 Message

Models: R420xr

1 128
Download 128 pages 61.61 Kb
Page 126
Image 126

Error Code

Message Information

 

 

Details

If the system event log fails to initialize, platform status and

 

 

failure events are not captured. Some management software

 

 

do not report platform exceptions.

 

Action

Reboot the management controller or iDRAC. Cycle system

 

 

input power. If problem persists call support.

SEL1204

Message

An unknown system hardware failure detected.

 

 

LCD Message

Unknown system hardware failure.

 

Details

If the system event log failed to initialize, platform status and

 

 

failure events are not captured. Some management software

 

 

do not report platform exceptions.

 

Action

Re-configure system to the minimum supported

 

 

configuration. If issues persists, contact support.

TMP0118

Message

The system inlet temperature is less than the lower warning

 

 

 

threshold.

 

LCD Message

System inlet temperature is outside of range.

 

Details

Ambient air temperature is too cool.

 

Action

Check the system operating environment.

TMP0119

Message

The system inlet temperature is less than the lower critical

 

 

 

threshold.

 

LCD Message

System inlet temperature is outside of range.

 

Details

Ambient air temperature is too cool.

 

Action

Check the system operating environment.

TMP0120

Message

The system inlet temperature is greater than the upper

 

 

 

warning threshold.

 

LCD Message

System inlet temperature is outside of range.

 

Details

Ambient air temperature is too warm or one or more fans

 

 

may have failed.

 

Action

Check the system operating environment and review event

 

 

log for fan failures.

TMP0121

Message

The system inlet temperature is greater than the upper

 

critical threshold.

126

Page 126
Image 126
Dell R420xr owner manual SEL1204 Message, TMP0118 Message, TMP0119 Message, TMP0120 Message, TMP0121 Message