Error Code | Message Information |
|
|
| Action | 1. | Turn off the system and remove input power for one |
|
| ||
|
|
| minute. |
|
| 2. | Ensure the processor is seated correctly. |
|
| 3. | Reapply input power and turn on the system. |
|
| 4. | If the issue persists, see Getting Help. |
CPU0701 | Message | CPU <number> protocol error detected. | |
| |||
| LCD Message | CPU <number> protocol error detected. Power cycle | |
|
| system. | |
| Details | System event log and operating system logs may indicate | |
|
| that the exception is external to the processor. | |
| Action | 1. | Check system and operating system logs for exceptions. |
|
| ||
|
|
| If no exceptions are found, continue. |
|
| 2. | Turn off the system and remove input power for one |
|
|
| minute. |
|
| 3. | Ensure the processor is seated correctly. |
|
| 4. | Reapply input power and turn on the system. |
|
| 5. | If the issue persists, see Getting Help. |
CPU0702 | Message | CPU bus parity error detected. | |
| |||
| LCD Message | CPU bus parity error detected. Power cycle system. | |
| Details | System event log and operating system logs may indicate | |
|
| that the exception is external to the processor. | |
| Action | 1. | Check system and operating system logs for exceptions. |
|
| ||
|
|
| If no exceptions are found, continue. |
|
| 2. | Turn off the system and remove input power for one |
|
|
| minute. |
|
| 3. | Ensure the processor is seated correctly. |
|
| 4. | Reapply input power and turn on the system. |
|
| 5. | If the issue persists, see Getting Help. |
CPU0703 | Message | CPU bus initialization error detected. | |
| |||
| LCD Message | CPU bus initialization error detected. Power cycle system. | |
| Details | System event log and operating system logs may indicate | |
|
| that the exception is external to the processor. |
114