Error Code

Message Information

 

PCI1342

Message

A bus time-out was detected on a component at slot

 

 

 

<number>.

 

Details

System performance may be degraded, or system may fail to

 

 

operate.

 

Action

Cycle input power, update component drivers, if device is

 

 

removable, reinstall the device.

PCI1348

Message

A PCI parity error was detected on a component at slot

 

 

 

<number>.

 

LCD Message

PCI parity error on slot <number>. Re-seat PCI card.

 

Details

System performance may be degraded, or system may fail to

 

 

operate.

 

Action

Cycle input power, update component drivers, if device is

 

 

removable, reinstall the device.

PCI1360

Message

A bus fatal error was detected on a component at slot

 

 

 

<number>.

 

LCD Message

Bus fatal error on slot <number>. Re-seat PCI card.

 

Details

System performance may be degraded, or system may fail to

 

 

operate.

 

Action

Cycle input power, update component drivers, if device is

 

 

removable, reinstall the device.

PDR0001

Message

Fault detected on drive <number>.

 

 

LCD Message

Fault detected on drive <number>. Check drive.

 

Details

The controller detected a failure on the disk and has taken

 

 

the disk offline.

 

Action

Remove and re-seat the failed disk. If the issue persists, see

 

 

Getting Help.

PDR1016

Message

Drive <number> is removed from disk drive bay <bay>.

 

 

LCD Message

Drive <number> removed from disk drive bay <bay>. Check

 

 

drive.

 

Details

The controller detected that the drive was removed.

 

Action

Verify drive installation. Re-seat the failed drive. If the issue

 

 

persists, see Getting Help.