5.5 Group 4: Input Function Parameters

 

 

 

VFD-F Series

5.5 Group 4: Input Function Parameters

 

 

 

 

 

 

04 - 00

Multi-function Input terminal 1

Factory Setting: 01

04 - 01

Multi-function Input terminal 2

Factory Setting: 02

 

04 - 02

Multi-function Input terminal 3

Factory Setting: 03

 

04 - 03

Multi-function Input terminal 4

Factory Setting: 04

 

04 - 04

Multi-function Input terminal 5

Factory Setting: 05

 

04 - 05

Multi-function Input terminal 6

Factory Setting: 07

 

04 - 06

Multi-function Input terminal 7

Factory Setting: 08

 

04 - 07

Multi-function Input terminal 8

Factory Setting: 09

 

 

Settings

00~31

 

 

 

 

 

 

Setting

 

Functions

Descriptions

 

 

 

 

00

No function

 

All unused terminals should be set to 00, to

 

assure they have no effect on drive operation.

 

 

 

01

Multi-Speed terminal 1

Allows selection of the 15 multi-step speeds.

02

Multi-Speed terminal 2

Please refer to 05-00 to 05-14 to program the

03

Multi-Speed terminal 3

15 step speeds.

04

Multi-Speed terminal 4

 

 

05

Reset (NO)

 

Clears (Reset) a fault and returns the AC drive

06

Reset (NC)

 

to normal operation.

07

Jog operation (JOG)

Enables the JOG command. Works identical

to the JOG key on the digital keypad.

 

 

 

 

 

 

Stops the acceleration or deceleration of the

08

Accel/Decel disable

AC drive. AC drive then maintains a constant

 

 

 

speed.

09

Accel/Decel 2 selection

A corresponding terminal set to value 09 and

closed selects Accel/Decel time 2. A

 

 

 

corresponding terminal set to value 10 and

10

Accel/Decel 3 selection

closed selects Accel/Decel time 3.

Accel/Decel time 4 is selected when both

 

 

 

terminals are closed.

11

B.B. (NO) input

Enables the base block (pause) function.

 

 

 

Please refer to Pr.08-08, for base block

12

B.B. (NC) input

functions.

13

Increase Frequency

Enables the external terminals to increase or

 

 

 

decrease the Master Frequency command

14

Decrease Frequency

each time an input is received. Terminals are

not active during a stop command.

 

 

 

15

Emergency stop (NO)

Generates an external fault (EF1). The

 

 

 

function is identical to the external terminal

16

Emergency stop (NC)

(EF).