Delta Electronics VFD-F Series manual ASCII mode, RTU mode

Models: VFD-F Series

1 161
Download 161 pages 45.18 Kb
Page 86
Image 86
Manual background

Manual background VFD-F Series

ASCII mode:

Command message:

STX

‘:’

ADR 1

‘0’

ADR 0

‘1’

CMD 1

‘1’

CMD 0

‘0’

Data

‘0’

Starting

‘5’

address

‘0’

Number

‘0’

‘0’

Of

‘0’

data

‘0’

(Word)

‘2’

Number of

‘0’

data (Byte)

‘4’

The first

‘1’

data

‘3’

 

‘8’

The second

‘8’

‘0’

data

‘F’

 

‘A’

LRC CHK 1

‘0’

‘9’

LRC CHK 0

‘A’

END 1

CR

END 0

LF

RTU mode:

Response message:

STX

‘:’

ADR 1

‘0’

ADR 0

‘1’

CMD 1

‘1’

CMD 0

‘0’

Data

‘0’

address

‘5’

 

‘0’

 

‘0’

Number

‘0’

Of

‘0’

data

‘0’

(Word)

‘2’

LRC CHK 1

‘E’

LRC CHK 0

‘8’

END 1

CR

END 0

LF

Error response message

STX

‘:’

ADR 1

‘0’

ADR 0

‘1’

CMD 1

‘9’

CMD 0

‘0’

Error

‘0’

code

‘2’

LRC CHK 0

‘6’

LRC CHK 1

‘D’

END 1

CR

END 0

LF

5

Command message:

 

Response message:

 

Error response message

ADR

01H

 

ADR

01H

 

ADR

01H

CMD

10H

 

CMD 1

10H

 

CMD 1

90H

Data starting

05H

 

Data starting

05H

 

Error

02H

address

00H

 

address

00H

 

CRC CHK LOW

CDH

Number of

00H

 

Number of

00H

 

CRC CHK HIGH

C1H

data (Word)

02H

 

data (Word)

02H

 

 

 

Number of data

04

 

CRC CHK LOW

41H

 

 

 

(Byte)

 

 

CRC CHK HIGH

04H

 

 

 

The first

13H

 

 

 

 

 

 

data

88H

 

 

 

 

 

 

The second

0FH

 

 

 

 

 

 

data

A0H

 

 

 

 

 

 

CRC CHK LOW

4DH

 

 

 

 

 

 

CRC CHK HIGH

D9H

 

 

 

 

 

 

DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED

5-53

Page 86