Fault

Fault Descriptions

Corrective Actions

Name

 

 

 

Analog Signal Error

1. Check ACI wiring.

 

2. Check whether the input current of ACI is

 

 

lower than Pr.04-13/04-17 setting.

 

Emergency stop.

 

 

When the multi-function

Press RESET after fault has been cleared.

 

input terminals (MI1 to

 

MI8) stop, AC drive

 

 

stops any output.

 

 

Internal memory IC

1. Return to the factory.

 

2. Check the EEPROM on the control

 

cannot be programmed.

 

 

board.

 

Internal memory IC

1. Return to the factory.

 

cannot be read.

2. Reset drive to factory defaults.

 

U-phase error

Return to the factory.

 

 

 

 

V-phase error

Return to the factory.

 

 

 

 

W-phase error

Return to the factory.

 

 

 

 

OV or LV

Return to the factory.

 

 

 

 

Isum error

Return to the factory.

 

 

 

 

OH error

Return to the factory.

 

 

 

 

Software protection

Return to the factory.

 

failure

 

 

 

Auto accel/decel failure

Don’t use the function of auto acceleration

 

/deceleration.

 

 