Preface
CHAPTER 2 STORAGE AND INSTALLATION
CHAPTER 3 WIRING
CHAPTER 1 RECEIVING AND INSPECTIONS
CHAPTER 4 DIGITAL KEYPAD OPERATION
CHAPTER 6 MAINTENANCE AND INSPECTIONS
CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS
CHAPTER 7 TROUBLESHOOTING AND FAULT INFORMATION
CHAPTER 8 SUMMARY OF PARAMETER SETTINGS
ACCESSORIES
APPENDIX A
APPENDIX B
CHAPTER 1 RECEIVING AND INSPECTION
1.2 Model Explanation
055F43A
1.3 Series Number Explanation
VFD-F Series
2.1 Storage
CHAPTER 2 STORAGE AND INSTALLATION
Ambient Conditions
2.2 Installation
Failure to observe these precautions may void the warranty
CHAPTER 3 WIRING
DANGER
Hazardous Voltage
Short Circuit Withstand
3.1 Basic Wiring Diagram
RESET
Setting
Brake Resistor
RESET
Setting
Brake Unit Optional
Brake Resistor
Wiring for SINK mode and SOURCE mode
1/2 Accel/Decel switch
1/2 Accel/Decel switch
Sink Sw1 Source
3.2 External Wiring
3.3 Main Circuit Connection
Terminal Explanations
Terminals +1, +2 for connecting DC reactor
Mains power terminals R/L1, S/L2, T/L3
Output terminals for main circuit U, V, W
When not used, please leave the terminals +2+2/B1, - open
3.4 Control Terminals
wind each wire 3 times or more around the core
Analog input terminals ACI1, ACI2, ACM
Digital inputs FWD, REV, MI1~MI8, DCM
ACI 1/2
3.5 Specifications for Power Terminals and Control Terminals
R/L1 S/L2 T/L3
MOTOR
POWER DC + DC
CHARGE
31MAX
POWER
26.5MAX
3.6 Wiring Notes PLEASE READ PRIOR TO INSTALLATION
Forward running
Page
3.7 Motor Operation Precautions
CHAPTER 4 DIGITAL KEYPAD OPERATION
4.1 VFD-PU01
RESET
STOP
4.1.1 Description of the Digital Keypad VFD-PU01
Descriptions
Display Message
Display the AC drive forward run status
Setting direction
4.1.3 Operation steps of the Digital Keypad VFD-PU01
START
To shift data
4.2 KPF-CC01
4.2.1 Description of the Digital Keypad KPF-CC01
4.2.2 Explanation of Display Message
Display Message
4.2.3 KPF-CC01 Operation Flow Chart
KPF-CC01 Operation Flow Chart
Display Message
Description
CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS
5.1 Group 0 AC Drive Status Parameters Group 0 is read-only
Display
This parameter displays output power factor
5.2 Group 1 Basic Parameters
Mid-point Voltage
01 - 09 Acceleration Time 01 - 10 Deceleration Time
JOG Frequency
01-23
Accel/Decel time unit
Accel/Decel time range
1 Sec
5.3 Group 2 Operation Method Parameters
Settings
Factory Setting 9000Hz
Factory Setting 6000Hz
Factory Setting 4000Hz
00 2-wire #1
01 2-wire #2
02 3-wire
02-05
= U LED special display
5-12
02 - 09 Special Display
This feature is only enabled when Pr. 02-00 is set for 0 or
Setting
5.4 Group 3 Output Function Parameters
Functions
Descriptions
Functions
Setting
Descriptions
External relay specifications = 8A/250VAC or 5A/30VDC
Setting 04 0-10V = 0.0 - output power factor
Setting
5.5 Group 4 Input Function Parameters
Descriptions
Functions
Setting
valid when Pr.02-01 is set to 00. Otherwise, the
Functions
Descriptions
AVI Minimum Voltage
Please refer to the following diagram for more details
Analog Input Delay AVI
5.6 Group 5 Multi-step Speed Frequency Parameters
Example 2 Pr.05-15 = 2 Continuously executes program cycles
Example 3 Pr.05-15 = 3 Execute one cycle step by step
PLC operation execution one cycle step by step
0=Forward 1=Reverse
Time Duration of 1st Step Speed
05-07
05-06
05-08
05-05
Deceleration characteristic
when Over-voltage stall
prevention enabled
5.7 Group 6 Protection Function Parameters
Over-current Stall Prevention during Acceleration
Over-current Stall Prevention during Operation
This parameter selects the Over-torque Detection operation
Operation
5 Timemin
60Hz or more
50Hz
10 Over current during acceleration ocA
06 - 17 Parameter Protection Password Setting Settings 00~65535
230V series
5.8 Group 7 AC Drive and Motor Parameters
460V series
No-load Current of Motor
Unsuitable setting value may cause over compensation
5.9 Group 8 Special Parameters
DC Braking Time
01 Trace from top downward 02 Trace from bottom upward
Momentary Power Loss Operation
Master frequency command
Synchronization attained
100% 70%
Automatic Energy-saving Operation
Unit
5-44
5.10 Group 9 Communication Parameters
Bit2 0 BB OFF, 1 BB ON
5-46
Start
Stop Stop
bit bit
7-bit character 10-bit character frame
7 , E , 1 9-04=0, 9-05=04
7 , O , 1 9-04=0, 9-05=05
8 , E , 1 9-04=1 or 2, 9-05=04
8 , O , 1 9-04=1 or 2, 9-05=05
ASCII mode
RTU mode
ASCII mode
RTU mode
ASCII mode
RTU mode
ASCII mode
RTU mode
ASCII mode
RTU mode
ASCII mode
RTU mode
Command message
Status monitor Read only
5-56
Content
CRC CHK High
5-58
Explanation
Exception
code
Page
10 - 03 Proportional Gain P
5-62
V/F Curve Diagram
Settings
Circulative Control
00 No function
5-64
5-65
M1 M2 M3 M4
5-66
11 - 02 Multiple Motors Control Settings 01~04
Output Frequency
In the following chart T1 enter sleep process time Pr.11-07
VFD-F Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
11 - 07 Enter Sleep Process Time
11 - 10 Treatment of Fixed Amount Circulation Malfunction
6.2 Periodic Maintenance
CHAPTER 6 MAINTENANCE AND INSPECTIONS
6.1 Periodic Inspection
This page intentionally left blank
VFD-F Series
CHAPTER 7 Troubleshooting and Fault Information
Common Problems and Solutions
Fault
Fault Descriptions
Fault Descriptions
Fault
Corrective Actions
Fault Descriptions
Fault
Corrective Actions
Fault Descriptions
Fault
Corrective Actions
Fault Descriptions
Fault
Corrective Actions
Fault Descriptions
Fault
Corrective Actions
CHAPTER 8 PARAMETER SUMMARY
Group 0 AC Drive Status Parameter
00-02
Group 1 Basic Parameter Twice the value for 460V class
Group 2 Digital Output/Input Parameter
02-07
Group 3 Output Function Parameters
37 PLC program operation
Group 4 Input Function Parameters
04-15
Group 5 Multi-step Speed Frequency Parameters
05-28
Group 6 Protection Function Parameters Twice the value for 460V class
06-14 Fourth Recent Fault Record
Group 7 AC Drive and Motor Parameters
Group 8 Special Parameters Twice the value for 460V class
Group 9 Communication Parameters
09-06
Group 10 PID Controls
Group 11 Fan and Pump Control Parameters
This page intentionally left blank
VFD-F Series
Specifications
General Specifications
Voltage Class
230V Class
Page
B.1 All Brake Resistors & Brake Units Used in AC Motor Drives
ACCESSORIES
Ì Standard 4-pole motor
9. Definition for Brake Usage ED%
B.1.1 Dimensions and Weights for Brake Resistors
Order P/N BR500W030, BR500W100, BR1K0W020, BR1K0W075
Order P/N BR1K0W050, BR1K2W008, BR1K2W6P8, BR1K5W005, BR1K5W040
Voltage Class
B.1.3 Dimensions for Brake Unit
R3.3 R0.13
Figure 1 VFDB2015, VFDB2022, VFDB4030, VFDB4045
VFD-F Series
Figure 2 VFDB4132
VFDB4132
VFD-F Series
CHARGE ACT OC OH
B.2 AMD-EMI Filter Cross Reference
Saddle on both ends Saddle on one end
VFD-F Series
B.3 AC Reactor
AC Input Reactor Recommended Value
AC Output Reactor Recommended Value
B-11
B.4 Non-fuse Circuit Breaker Chart
11.2
B.5 Fuse Specification Chart
B-13
B.6 PU06
RESET
Status indicator
Status indicator
XX-XX
B.6.3 PU06 Operation Flow Chart
XXXXX -ERR- -END
B.7 Relay Card
PCB-SUPPORT
PCB-SUPPORT
VFD-F Series
B.8 Zero Phase Reactor RF220X00A
Dimensions are in millimeter and inch
Note 600V Insulated unshielded Cable Diagram A
Diagram B
Frame B
DIMENSIONS
Frame
Frame
Frame C
VFD110F43A VFD110F43H VFD150F43A VFD150F43H
Frame
Frame D
VFD300F43A VFD300F43H
Frame E
Frame
W W1 H1
D D1
RESET
JOG MODE
Frame G
Frame
Frame H
Frame
Frame HH1 VFD1850F43A VFD1850F43H VFD2200F43A VFD2200F43H
MODE
JOG MODE
RUN STOP
VFD-PU01
Unit mm inches
KPF-CC01 Unit mm inches
VFD-F Series