Delta Electronics VFD-F Series manual ASCII mode, RTU mode

Models: VFD-F Series

1 161
Download 161 pages 45.18 Kb
Page 84
Image 84
Manual background

Manual background VFD-F Series

zCommand code: 06H, write a word

For example, writing 6000(1770H) to address 0100H of AMD with address 01H.

ASCII mode:

Command message:

STX

‘:’

ADR 1

‘0’

ADR 0

‘1’

CMD 1

‘0’

CMD 0

‘6’

data

‘0’

starting

‘1’

address

‘0’

 

‘0’

data

‘1’

 

‘7’

 

‘7’

 

‘0’

LRC CHK 1

‘7’

LRC CHK 0

‘1’

END 1

CR

END 0

LF

RTU mode:

Response message:

STX

‘:’

ADR 1

‘0’

ADR 0

‘1’

CMD 1

‘0’

CMD 0

‘6’

data

‘0’

starting

‘1’

address

‘0’

 

‘0’

data

‘1’

 

‘7’

 

‘7’

 

‘0’

LRC CHK 1

‘7’

LRC CHK 0

‘1’

END 1

CR

END 0

LF

Error response message

STX

‘:’

ADR 1

‘0’

ADR 0

‘1’

CMD 1

‘8’

CMD 0

‘6’

Error

‘0’

code

‘2’

LRC CHK 0

‘6’

LRC CHK 1

‘D’

END 1

CR

END 0

LF

5

Command message:

 

Response message:

 

Error response message

 

 

 

 

 

 

 

 

ADR

01H

ADR

01H

ADR

01H

CMD

06H

 

CMD 1

06H

 

CMD 1

86H

data

01H

 

data

01H

 

Error code

02

Starting address

00H

 

Starting address

00H

 

CRC CHK LOW

C3H

data

17H

 

data

17H

 

CRC CHK HIGH

A1H

 

00H

 

 

70H

 

 

 

CRC CHK LOW

87H

 

CRC CHK LOW

87H

 

 

 

CRC CHK HIGH

C6H

 

CRC CHK HIGH

C6H

 

 

 

DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED

5-51

Page 84
Image 84
Delta Electronics VFD-F Series manual ASCII mode, RTU mode