Delta Electronics VFD-F Series manual Status monitor Read only, 5-56

Models: VFD-F Series

1 161
Download 161 pages 45.18 Kb
Page 89
Image 89
Status monitor Read only

5-56 VFD-F Series

3.5 Address List

The contents of available addresses are shown as below:

Content

AC drive

Parameters

Command Write only

Status monitor Read only

Address

GGnnH

2000H

2001H

2002H

2100H

Function

GGmeans parameter group, nn means parameter number, for example, the address of Pr 04-01 is 0401H. Referencing to chapter 5 for the function of each parameter. When reading parameter by command code 03H, only one parameter can be read at one time.

00B: No function

Bit 0-1

01B: Stop

10B: Run

 

 

11B: Jog + Run

Bit 2-3

Reserved

 

00B: No function

Bit 4-5

01B: FWD

10B: REV

 

 

11B: Change direction

 

00B: Comm. forced 1st accel/decel

Bit 6-7

01B: Comm. forced 2nd accel/decel

10B: Comm. forced 3rd accel/decel

 

 

11B: Comm. forced 4th accel/decel

Bit 8-11 Represented 16 step speeds.

Bit 12

0: No comm. multi step speed or accel/decel time

1: Comm. multi step speed or accel/decel time

 

Bit 13-15

Reserved

Frequency command

Bit 0

1: EF (external fault) on

Bit 1

1: Reset

Bit 2

1: External Base Block (B.B) on

0: External Base Block (B.B) off

 

Error code:

 

00:No fault occurred

01:Over-current (oc)

02:Over-voltage (ov)

03:Overheat (oH)

04:Overload (oL)

05:Electronic thermal relay (oL1)

06:EF (external fault)

07:AC drive IGBT fault (occ)

08:CPU failure (cF3)

09:Hardware protection failure (HPF)

10:Over current during acceleration (ocA)

11:Over current during deceleration (ocd)

12:Over current during steady state operation (ocn)

13:Ground Fault (GFF)

5-56

DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED

Page 89
Image 89