CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

VFD-F Series

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

: This parameter can be set during operation.

5.1Group 0: AC Drive Status Parameters Group 0 is read-only.

00 - 00

Software Version

 

 

Factory setting: Read Only

 

 

 

 

 

 

 

 

 

This parameter displays the software version of AC drive.

 

 

 

 

 

 

 

00 - 01

AC Drive Status Indication 1

 

 

Factory setting: Read Only

 

 

 

 

 

 

 

 

 

This parameter displays the AC drive status.

 

 

 

 

 

 

 

 

 

Code

 

AC Drive Status

 

 

Explanation

 

00

No fault occurred

 

 

 

 

 

01

oc

 

over current

 

 

02

ov

 

over voltage

 

 

03

oH

 

over temperature

 

 

04

oL

 

overload

 

 

05

oL1

 

electronic thermal relay

 

 

06

EF (external fault)

 

EF-DCM is closed

 

 

07

occ (AC drive IGBT fault )

 

IGBT short circuit protection

 

 

08

cF3 (CPU failure)

 

Abnormal A/D reading during self-check

 

 

09

HPF (hardware protection failure)

 

Hardware protection function activated

 

 

 

 

 

 

during self-check.

 

 

10

ocA (over current during acceleration)

 

Output current exceeds protection level

 

 

 

 

 

 

during acceleration

 

 

11

ocd (over current during deceleration)

 

Output current exceeds protection level

 

 

 

 

 

 

during deceleration

 

 

12

ocn (over current during steady state

 

Output current exceeds protection level

 

 

 

operation)

 

during steady state operation.

 

 

13

GFF (ground fault)

 

Ground fault protection feature activated

 

 

14

Lv (under voltage)

 

Low input voltage

 

 

15

cF1

 

EEPROM input data is abnormal

 

 

16

cF2

 

EEPROM output data is abnormal

 

 

17

bb (base block)

 

BB is set and activated

 

 

18

oL2 (motor over load 2)

 

Output current exceeds rated motor current

 

 

19

Reserved

 

 

 

 

 

20

codE

 

software or password protection

 

 

21

EF1 (external emergency stop)

 

EF1 (a multifunction-DCM is enabled)

 

 

22

PHL (phase loss)

 

Input power lacks phase.

 

 

 

 

 

 

3-phase input power is unbalance and

 

 

 

 

 

 

exceeds specification.

 

 

23

Lc (Low Current)

 

Low current detection during operation.

 

 

24

FbL(Feedback Loss)

 

Feedback signal is abnormal.

 

 

25

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED