boardmon

the state of the signaling bits and alarms. It also counts the errors (e.g., framing errors, CRC errors, clock slips, BPVs) on each span. It only works with spans that are configured for robbed-bit signaling and where telephony connections have been made.

The spans are numbered starting from 1 which is the first interface on a module.

The btcall.cfg file is the user configuration file. The boardmon application is found in the bapp.src directory.

Command Syntax

boardmon [-m <mod>] [-s <span>] [-d] [-v] [-h]

Arguments

 

-m <mod>

Use specified module (default 2)

-s <span>

Use specified span only [1-4] (default all)

-d

Enable program debug mode

-v

Enable Bfv API debug mode

-h

Help

While the program is running you can press a key to reset the error counters or to quit. When running under Unix, you must press Enter after pressing the key.

1Reset error counters for span 1

2Reset error counters for span 2

3Reset error counters for span 3

4Reset error counters for span 4

r or R Reset error counters for all spans

q or Q Quit the program