Enabling the R2 Protocol

 

 

 

 

 

 

 

 

 

 

 

Table 18. R2 Digital Line Signaling Parameters (Continued)

 

 

 

 

 

 

 

 

 

 

 

Name

 

 

Description

 

Units

Range

 

 

 

 

 

 

 

 

 

 

 

c_d_cas_bits

 

 

Specification of the CAS C

 

 

 

0: CD=00

 

 

 

 

bit and D bit settings.

 

 

 

1: CD=01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2: CD=10

 

 

 

 

 

 

 

 

3: CD=11

 

 

 

 

 

 

 

 

 

 

 

ClearbackControl

 

 

Used by the outbound side

 

 

 

0: release guard

 

 

 

 

to determine whether the

 

 

 

1: forced release

 

 

 

 

network will use a release

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

guard (AB=11) or a forced

 

 

 

 

 

 

 

 

 

release (AB=00) signal to

 

 

 

 

 

 

 

 

 

tear down a call, The

 

 

 

 

 

 

 

 

 

selected signal is handled

 

 

 

 

 

 

 

 

 

accordingly, while the

 

 

 

 

 

 

 

 

 

other is simply ignored.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 19 identifies the IISDN_R2_INTERREGISTER_PARAMS

 

 

sub-structure containing the parameters required used to configure

 

 

the MFC inter-register signaling.

 

 

 

 

 

Table 19. R2 MFC Inter-register Signaling Parameters

 

 

 

 

 

 

 

 

Name

 

Description

 

Units

Range

 

 

 

 

 

 

The Following Parameters Can Be Modified According to Application Requirements:

 

 

 

 

 

 

 

 

dnisMaxNumDigits

 

Maximum number of DNIS digits

 

 

[0-IISDN_MAX_

 

 

 

required.

 

 

 

DIGITS]

 

 

 

 

 

 

 

 

 

aniMaxNumDigits

 

Maximum number of ANI digits

 

 

 

[0-IISDN_MAX_

 

 

 

required.

 

 

 

DIGITS]

 

 

 

 

 

 

 

 

 

dnisNumDigitsBeforeANI

 

The number of DNIS digits to

 

 

 

[1...N], where N =

 

 

 

collect before requesting ANI.

 

 

 

dnisMinNumDigits

 

 

 

 

 

 

 

interForwardToneTimeOut

 

Period associated with the inbound

Seconds

Typically, set to [8-24],

 

 

 

channel “T3” timer that supervises

 

 

but refer to network

 

 

 

the interval elapsing between

 

 

 

specification.

 

 

 

recognition of two consecutive

 

 

 

 

 

 

 

forward tones. (Ref. ITU Q.476).

 

 

 

 

 

 

 

 

 

 

 

 

prePulseToneDelay

 

The interval from the end of the

 

ms

Set to >= 100

 

 

 

last backward signal and the start

 

 

 

 

 

 

of a backward pulse signal

 

 

 

 

 

 

 

(Ref. ITU Q.442).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

November 2009