General Information
The protocols describe the value and meaning of the signaling bits and the timing between changes in their value.
Brooktrout modules support the following LEC protocols:
E&M Wink Start
E&M Immediate Start
E&M Delay Dial
FXO Loop Start
FXS Loop Start
FXO Ground Start
FXS Ground Start
All signaling modes support pulsed (10 pulses per second), DTMF and MF dialing. However, detection of digits must be handled by the host.
ITU's R2 protocol, normally used in E1 lines is also supported, and it is described in Using the BSMI R2 Signaling Capability on page 336.
Wink Start, Immediate Start and Delay Dial protocols are typically used to connect equivalent devices (for example, Central Offices). The same protocol must be loaded on both channel involved in a call. Loop Start and Ground Start protocols connect different types of devices (a Central Office or PBX to a Station). In this case the side acting as Central Office must load the FXO (foreign exchange office) version of the protocol, while the Station side must load the FXS (foreign exchange station) version.
The messages and data structures used for the host application and the module to communicate form the BSMI interface, described in Volume 5 of the Bfv API Reference Manual. The same Bfv API is used also for ISDN and R2 — the same messages are used to control/notify similar events across all protocols.
Structure IISDN_BCHANNEL_ID contains fields common to all CAS protocols plus data structures containing LEC- and
November 2009 | 266 |