Appendix D IBM ProPrinter 4207, 4208 XL 24 Quick Reference
Table 7: Further Control Sequences, supported by
IBM Emulation Mode (Native Commands)
Escape Sequence | Mnemonic Function |
|
|
|
| ||
|
|
|
|
| |||
ESC [ |
| $$ | Control String Introducer (CSI) for 'ESC [' |
| |||
ESC |
| $$/ | Control String Introducer (CSI) for 'ESC' |
| |||
ESC * P1 P2 P3 v1 . . . vn |
| Select Various Graphics Modes |
|
| |||
|
|
| P2 + P3 * 256 = number of columns |
| |||
|
|
|
|
| (P2,P3 = 0/0...F/F) | ||
|
|
| v1 .. vn = binary data in hex code |
| |||
Parameter Table Graphic Density: |
|
|
|
|
| ||
P1 | Graphic type | dots | max. | hor. | vert. | vert. |
|
|
| per | of | density | density | density |
|
|
| column | columns | ( dpi ) | no AGM | AGM |
|
0/0 | Standard Density (K) | 8 | 816 | 60 | 72 | 60 |
|
0/1 | Double Density (L) | 8 | 1632 | 120 | 72 | 60 |
|
0/2 | 2xDensity / 2xSpeed (Y) 8 | 1632 | 120 | 72 | 60 | *) | |
0/3 | Quadruple Density (Z) | 8 | 3264 | 240 | 72 | 60 | *) |
0/4 | CRT I | 8 | 1088 | 80 | 72 | 60 |
|
0/5 | Plotter | 8 | 979 | 72 | 72 |
|
|
0/6 | CRT II | 8 | 1224 | 90 | 72 | 60 |
|
0/B | Double Density Plotter | 8 | 1958 | 144 | 72 |
| *) |
2/0 | Standard Density | 24 | 816 | 60 | 180 | 180 |
|
2/1 | Double Density | 24 | 1632 | 120 | 180 | 180 |
|
2/6 | CRT III | 24 | 1224 | 90 | 180 | 180 |
|
2/7 | Triple Density | 24 | 2448 | 180 | 180 | 180 |
|
2/8 | Hex Density | 24 | 4896 | 360 | 180 | 180 | *) |
*) consecutive horizontal dots cannot be printed.
Example: box 8x8 dots with center point 2x2 dots, standard density, 8 dots / column hex: 1B 2A 00 08 00 FF 81 81 99 99 81 81 FF