Maintenance

To Install the Platen

Ensure that the printer is switched OFF.

1.Place platen (2) in the vacant space between print head and metal bar.

2.Move print head from its right hand position into the centre.

3.Fit the gear wheel end of the platen into the right hand side mounting. Be careful not to damage the gear wheel.

4.Ensure that the plastic platen clamp (1) is in the upright position, push the platen in to its mounting and lock in position by pushing the tag on the clamp to the rear.

5.Install the ribbon cassette.

6.Fit and close the top cover.

7.Fit the output stacker stacker (only printer CI - 4050).

8.Run the MENU-function AGC ADJUST with ink ribbon cassette installed but no paper inserted.

4-7