Appendix D IBM ProPrinter 4207, 4208 XL 24 Quick Reference

Table 7 (Cont.): Further Control Sequences, supported by

IBM Emulation Mode (Native Commands)

Escape Sequence

Mnemonic

Function

 

 

 

 

 

ESC [ P1 ; P2 SP r

SM #

Select Macro and Change Emulation

 

 

P1

= 1: Macro 1

 

 

 

P1

= 2: Macro 2

 

 

 

P1

= 3: Macro 3

 

 

 

P1

= 4: Macro 4

 

 

 

P2

= 0: no change of emulation

 

 

P2

= 1: EPSON Emulation

 

 

 

P2

= 2: IBM ProPrinter Emulation

 

 

P2

= 3: IBM ProPrinter AGM Emulation

 

 

P2

= 4: EPSON Emulation

 

ESC M

RLF

Reverse Line Feed

 

ESC [ < s

EJF

Eject Form

 

 

ESC [ P1 ; P2 SP B

GSM

Graphic Size Modification

 

 

 

P1

= 1 0 0 : normal height

 

 

 

P1

= 2 0 0 : normal height

 

 

 

P1

= 3 0 0 : normal height

 

 

 

P1

= 4 0 0 : quadruple height

 

 

 

P1

= max. 8 0 0 in steps of 100

 

 

 

P2

= 1 0 0 : normal width

 

 

 

P2

= 2 0 0 : double width

 

 

 

P2

= 3 0 0 : triple width

 

 

 

P2

= 4 0 0 : quadruple width

 

 

 

P2

= max. 8 0 0 in steps of 100

 

 

Graphic Size Modification for DATA LARGE

 

 

P1

= 1 0 0 :

normal height

 

 

 

P2

= 1 0 0 :

normal width

 

 

 

P1 and P2 max. 9 9 0 0 in steps of 100

ESC [ P1 `

HPA

Set Horizontal Position Absolute

 

 

P1

= print column

(P1 = 0...9999)