Safety Information
Cable Routing for LAN Systems
The BlackDiamond 12800 series switches meet the requirements for LAN system equipment. LAN systems are designed for
This equipment can be connected between buildings if any one of the following conditions is true:
●Cable runs between buildings are less than 140 feet long.
●Cable runs between buildings are directly buried.
●Cable runs between buildings are in an underground conduit, where a continuous metallic cable shield or a continuous metallic conduit containing the cable is bonded to each building grounding electrode system.
CAUTION
Failure follow these requirements for cable routing conditions may expose the user to electrical shock and expose the unit to errors or damage.
PoE Devices
When connecting power over Ethernet (PoE) devices to a PoE switch, all connections between the PoE device and the switch must remain inside the same building and use a
Selecting Power Supply Cords
Extreme Networks provides power input cords shipped in the product box for use in the US and Canada. Power supply cords for use outside of the United States and Canada are typically provided separately by
The following are power cord requirements for use on Extreme switches:
Black Diamond SSI AC PSU Model 60020:
●Wire: 16 AWG (1.31 mm2) minimum,
●Wall plug: Suitable for use in country of installation & approved by local regulatory authority
●Device connector:
●Power cord assembly: Must be rated at 10A by