The front panel of the 700/1200 W AC PSU provides status LEDs. Table 11 describes the LED activity.
Table 11: LEDs on the 700/1200 W AC PSU
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Power |
|
|
|
|
|
| ||
|
|
|
| Fail | |||||
| Predictive Fail | ||||||||
PSU Condition | Green | Amber | Amber | ||||||
|
|
|
|
|
|
|
|
|
|
Power supply AC outputs working normally | On | Off | Off | ||||||
AC input power present/standby output on | Blinking | Off | Off | ||||||
Current limit on 48 VDC output | On | Off | Blinking | ||||||
Predictive failure | On | Blinking | Off | ||||||
No input power to this PSU only | Off | Off | On | ||||||
No input power to any PSU | Off | Off | Off | ||||||
Power supply failure | Off | Off | On | ||||||
|
|
|
|
|
|
|
|
|
|
Power Supply Cords
Extreme Networks 700/1200 W AC PSU(s) are shipped with both 110 V AC and 220 V AC power supply cords. The 110 V AC power supply cord allows for a maximum DC output power of 700 W. The 220V AC power supply cord allows for a maximum DC output power of 1200 W.
All power supply cords provided by Extreme Networks are designed for use in North America only. Power supply cords for use outside of North America are typically provided by a
●Power supply cords must be agency certified for country of use.
●Power supply cords must contain an IEC 320 C13 connector on the end of the PSU.
●Power supply cords must contain an appropriately rated and approved wall plug applicable to the country of installation.
●Power supply cords must be less than 5 m long.
●Wire size must be a minimum of 16 AWG (1.0 mm2)
WARNING!
Always be sure that the source outlet is properly grounded before plugging the AC power cord into the Extreme Networks 700/1200 W AC PSU.
Fuse
The Extreme Networks 700/1200 W AC PSU line and neutral legs are both fused. Power to the switch may still be live if the neutral fuse is open. This is not a field operator replaceable fuse. In the event of failure, immediately return the Extreme Networks 700/1200 W AC PSU for a complete replacement.
WARNING!
Field operators must not attempt to configure or replace fuses in Extreme Networks 700/1200 W AC PSUs. In the event of failure, immediately return the defective 700/1200 W AC PSU for a complete replacement.