Force10 Networks 100-00055-01 manual pnic getmachashindex, value for an IP address pairs

Models: 100-00055-01

1 132
Download 132 pages 61.04 Kb
Page 89
Image 89
pnic getmachashindex

Example Figure 53 pnic flow-teardown-enable Command Example

[root@localhost SW]# pnic flow-teardown-enable No card number specified. Assuming card 0

***Enabling Flow-Teardown on card:0 successful.

[root@localhost SW]#

Usage Information

Related Commands

The flow teardown feature is coupled with the firewall feature. When default drop mode is enabled (command pnic default-drop-enable), the flow teardown is enabled by default. When default drop mode is disabled (pnic default-drop-disable), the flow teardown is disabled by default.

pnic default-drop-disable

Disable firewall functionality. This is the default behavior.

pnic default-drop-enable

Enable firewall functionality.

 

 

pnic getmachashindex

Syntax

Parameters

Command History

Example

Display the hash index value for a specific source and destination IP address combination.

pnic getmachashindex [number]

number

Enter the number of the network interface card.

 

Range: 0-5

 

Default: 0

 

 

 

 

 

 

Version 2.1.0.0

Introduced

 

 

 

Figure 54 pnic getmachashindex Command Example

[root@localhost SW]# pnic getmachashindex No card number specified. Assuming card 0

Please input the Source IP address [e.g. 192.168.15.22]: 10.14.122.21

Input the Destination IP address [e.g. 172.168.15.14]: 154.12.123.44

The hash index calculated for MAC rewrite is: 170 (0xaa)

[root@localhost SW]#

Usage

Use this command with the MAC rewrite feature. This command displays the hash index

Information

value for an IP address pairs.

P-Series Installation and Operation Guide, version 2.3.1.2

89