Chapter 6 Daily Care
3When you press the [Send to] and [Scan/Stop] buttons at the same time, the feed/eject rollers rotate a certain amount.
Check
Function
Send to
[Send to] button
Scan /Stop
[Scan/Stop] button
Power
Be careful not to touch the rollers with your hand while they are rotating.
4Put a piece of cloth moistened with Cleaner F1 or a sheet of Cleaning Wipe against the roller surface, and wipe horizontally. Wipe the whole surface by pressing the [Send to] and [Scan/Stop] buttons at the same time to rotate the rollers.
Make sure that it is cleaned properly because residue on the roller will affect the feeding performance.
As a guideline, pressing the [Send to] and [Scan/Stop] buttons seven times will rotate the feed/eject rollers one revolution.
4 Close the ADF.
For details, refer to "1.4 Opening/Closing the ADF" (page 24).
Confirm that the ADF is closed properly. Otherwise, the
!document may not be fed into the ADF.
114