Chapter 4 How to Use the Operator Panel

Indications on Function Number Display

 

 

 

 

Display

Description

 

 

 

 

 

 

 

 

E

Indicates that a device error (alarm) occurred during

Display

Description

 

F

initialization or scanning.

 

 

 

C

The display will switch between either "E'", "F", "C", "H", "A"

8

Displayed when the scanner has just been powered on.

 

H

or "L", and an "alarm number".

 

 

 

 

 

 

A

For information about the error details, refer to "Device

P

Processing initialization.

 

L

Errors" (page 128).

 

 

 

0

Initialization is almost complete.

 

 

The display will return to ready ("1") if the [Scan/Stop] or

 

 

[Send to] button is pressed.

 

 

 

 

1

Ready to start scanning.

 

 

When this alarm occurs, turn the power off then back on.If

 

Indicates that the initialization was successfully completed.

 

 

the problem persists after turning the power back on,

 

This is referred to as "ready" status.

 

 

contact your FUJITSU scanner dealer or an authorized

 

 

 

 

FUJITSU scanner service provider.

Function

A function number will flash after detecting a multifeed.

 

 

 

 

 

 

None

The display switches off when the scanner enters power

number

This indication prompts whether or not to memorize the

 

(flash)

overlap pattern.

 

 

saving mode.

 

For details, refer to "Ignoring Multifeed for a Set Pattern"

 

 

 

 

 

 

 

 

(page 105).

 

 

 

 

 

 

 

 

c

Indicates that the ADF was opened when the status was

 

 

 

(flash)

ready ("1").

 

 

 

 

Note that the LED indicator will also flash.

 

 

 

 

To return to ready ("1") status, close the ADF by

 

 

 

 

For details, refer to "1.4 Opening/Closing the ADF" (page

 

 

 

 

24).

 

 

 

 

If the display does not return to ready ("1") after closing the

 

 

 

 

ADF, turn the power off then back on.If the problem still

 

 

 

 

persists, contact your FUJITSU scanner dealer or an

 

 

 

 

authorized FUJITSU scanner service provider.

 

 

 

 

 

 

 

 

P

Indicates that the scan was paused by pressing the [Send

 

 

 

(flash)

to] button.

 

 

 

 

Press the [Scan/Stop] button to resume the scan.

 

 

 

 

 

 

 

 

J

Indicates that a temporary error occurred during scanning.

 

 

 

U

The display will switch between either "J" or "U", and an

 

 

 

 

"error number".

 

 

 

 

For information about the error details, refer to "Temporary

 

 

 

 

Errors" (page 127).

 

 

 

 

The display will return to ready ("1") if the [Scan/Stop] or

 

 

 

 

[Send to] button is pressed.

 

 

 

 

 

 

 

 

65