2. WIRING
TB801
TB board
TB801
Coaxial cable
TB802
Pass the signal cable | Clamp shield of coaxial cable. | |
|
Grounding point for the shield.
Antenna unit, port side view
6.Confirm that armor is grounded between two flat washers.
7.Coat the screw part of the clamping gland with silicone sealant and tighten it.
8.Using the opener, insert each core (except coaxial cable) to appropriate connector plug on the TB801.
9.Loosen two screws and slide the TB board assembly upward and pull out it.
10.Connect the coaxial cable to TB802 on the TB board and clamp the shield with the cable clamp on the TB board.
Wiring for WAGO connector
Press downward.
Terminal opener
Wiring for Coaxial cable
Clamp shied with bracket.
Wire
Twist
WAGO connector
Tighten conductor with screw.
Procedures
1.Twist the conductor.
2.Press the terminal opener downward.
3.Insert the wire to hole.
4.Remove the terminal opener.
5.Pull the wire to confirm that it is ecure.
CAUTION
Do not use
11.Remount the TB board assembly.
12.Connect the shield wire to the grounding point as shown in the figure above.
13.Seal the cable gland with putty.