4. INSTALLING OPTIONAL EQUIPMENT

Setting method 1: DIP switch settings and gyrocompass specifications

1) Gyrocompass type

Gyrocompass

SW

SW

SW

JP1

type

1-4

1-5

1-6

 

 

 

 

 

 

AC

OFF

OFF

OFF

#1, #2,

synchronous

 

 

 

#3

DC

OFF

OFF

OFF

#2, #3,

synchronous

 

 

 

#4

DC step

ON

OFF

OFF

#4, #5,

 

 

 

 

#6

Full-wave

OFF

ON

OFF

#4, #5,

pulsating current

 

 

 

#6

Half-wave

ON

ON

OFF

#4, #5,

pulsating current

 

 

 

#6

2) Frequency

Frequency

SW

SW

Remarks

1-7

1-8

 

 

 

 

 

 

50/60 Hz

OFF

OFF

AC synchronous

pulsating current

 

 

 

400 Hz

ON

OFF

AC synchronous

pulsating current

 

 

 

 

 

 

 

500 Hz

OFF

ON

AC synchronous

pulsating current

 

 

 

DC

ON

ON

DC synchronous

DC step

 

 

 

3) Rotor Voltage (between R1 & R2)

4) Stator Voltage (between S1 & S2)

Rotor Voltage

SW

JP3

2-1

 

 

 

 

 

20 to 45 VAC

ON

#2

 

 

 

30 to 70 VAC

OFF

#2

 

 

 

40 to 90 VAC

ON

#1

 

 

 

60 to 135 VAC

OFF

#1

 

 

 

Stator

SW

SW

JP2

Voltage

2-2

2-3

 

 

 

 

 

20 to 45 VAC, or

ON

OFF

#2

20 to 60 VDC

 

 

 

30 to 70 VAC, or

OFF

OFF

#2

40 to 100 VDC

 

 

 

40 to 90 VAC

ON

OFF

#1

 

 

 

 

60 to 135 VAC

OFF

OFF

#1

 

 

 

 

5) Ratio

 

 

 

6) Supply Voltage

 

 

 

 

 

 

 

 

 

 

Ratio

SW

SW

SW

 

Stator

JP4

JP5

1-1

1-2

1-3

 

Voltage

 

 

 

 

360X

OFF

OFF

OFF

 

20 to 45 VAC, or 20 to 60 VDC

#2

#2

 

 

 

 

 

 

 

 

180X

ON

OFF

OFF

 

30 to 70 VAC, or 40 to 100 VDC

#1

#1

 

 

 

 

 

 

 

 

90X

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

36X

ON

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

7)AD-10 format data Tx interval

Select data transmitting interval for ports 1 to 6 with jumper wires JP6 and JP7: #25 for 25 ms, #200 for 200 ms.

Note: The Tx interval is available in 25 msec or 200 msec. Use 25 msec for radar.

8)NMEA-0183

Tx interval and Output sentence

Tx

SW

SW

Output

interval

2-5

2-6

sentence

 

 

 

 

1 s

OFF

OFF

HDT+VHW

200 ms

ON

OFF

HDT

100 ms

OFF

ON

HDT

25 ms

ON

ON

HDT

9)NMEA-0183 Version no.

Version no. SW3-1

1.5OFF

2.0ON

10)NMEA-0183 Baud rate

Baud rate

SW3-2

4860bps

OFF

38400bps

ON

11)Power fail detection

Talker

SW3-3

Disable

OFF

Enable

ON

(Use OFF for radar.)

12)Stator signal breaking detection

Detection SW2-7

Execute

OFF

No execute

ON

SW2-4: factory use only

SW3-4: not used

4-6

Page 68
Image 68
Furuno 2837S, 2137S-BB installation manual Rotor Voltage between R1 & R2 Stator Voltage between S1 & S2