4. INSTALLING OPTIONAL EQUIPMENT

4.Connect the GYRO CONVERTER board and J602 with two connector assemblies 03-2089 and 03-2090.

2Connection for J602

J602

 

PPL

 

 

 

From J4

 

7

 

BLU

 

 

 

 

 

 

6

 

 

GRN

 

 

 

5

 

 

YEL

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

ORG

 

 

 

 

 

3

 

 

RED

 

 

 

 

 

 

From J5

 

2

 

 

BRN

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

2VH connector assy.

03-2089 (5P)

Wiring for WAGO connector

Press downward.

Terminal opener

WAGO connector

Twist

Wire

Procedures

1.Twist the cores

2.Press the terminal opener downward.

3.Insert the wire to hole.

4.Remove the terminal opener.

5.Pull the wire to confirm that it is secure.

1

Connection for P608

P608

 

 

 

4

 

 

YEL

 

 

 

 

 

 

ORG

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

RED

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

BRN

 

 

 

 

 

 

 

 

 

 

 

 

 

1NH connector assy. 03-2091 (5P)

2VH connector assy.

03-2090 (3P)

To J602

 

 

 

 

P5

To P608

 

P4

P7

P603

XH-PH connector assy. 03-2088 (6-14P)

P1

12

 

 

J5

GYRO CONVERTER

 

 

 

4

 

J4

64P1106A

 

 

1

 

P608

 

1

 

 

 

 

3

J7

 

 

 

3

 

 

 

1

 

 

 

 

 

7

J602

1

 

J603

 

 

 

5

21

1

 

 

1

 

 

 

 

12

TB

 

 

 

 

 

 

 

 

03P9342

 

J1

1

1

Connecting connector assemblies

4-3

Page 65
Image 65
Furuno 2837S, 2137S-BB installation manual Connecting connector assemblies, Wiring for Wago connector