2. WIRING

Cable fabrication for the cables connected to the 03P9342 board

Signal cable RW-9600 (Between antenna unit and processor unit)

Vinyl sheath

Armor

 

 

60

Shield

450

5

Vinyl tape

After exposing cores,

 

wind shield around the armor.

 

 

6

 

 

 

14 5 9

 

Coaxial cable

Conductor

Clamp here by cable clamp.

Fold back shield.

 

 

 

 

Coaxial cable

Other cables for optional units

Use TTYCS-1 or TTYCS-4 (Japan standard cable) or equivalent.

Armor

Sheath

Shield

φ= 10.1 mm Conductor

S= 0.75 mm2 φ = 1.11 mm

TTYCS-1

Armor

 

60: Peel paint.￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

φ= 18.5 mm

Armor

Sheath

Shield

Conductor

S= 0.75 mm2 φ = 1.11 mm

 

TTYCS-4

 

Shield

 

 

 

L= Depends on equipment

L

 

 

connected. Measure at

 

 

 

 

 

the processor unit.

 

 

 

Vinyl tape

After exposing cores,

wind shield around the armor.

 

 

6

Clamp here by cable clamp.

Wiring for WAGO connector

Press downward.

Terminal opener

Wiring for Coaxial cable

Clamp shied with bracket.

Wire

Twist

WAGO connector

Tighten conductor with screw.

Procedures

1.Twist the conductor.

2.Press the terminal opener downward.

3.Insert the wire to hole.

4.Remove the terminal opener.

5.Pull the wire to confirm that it is ecure.

CAUTION

Do not use crimp-on lug to prevent contact resistance from increasing.

2-10