3. SETTING AND ADJUSTMENT

TT PRESET menu setting

Open the TT PRESET menu by pressing [6] key on the INITIALIZE menu.

[TT PRESET]

1BACK

2TT DATA OUTPUT OFF/TTM/TTD REL/TRUE 4800/9600/ 19200/38400

3MAX RANGE 24/32

4ECHO LEVEL

16

5QV DISPLAY OFF/ON

6TT W/O GYRO*

OFF/ON

7[TT PRESET]

8[TRACK PRESET]

9[TT SENSOR DATA]

0DEFAULT

 

[TT PRESET]

1

BACK

2

LAND SIZE

 

1200 M

3

ANT SELECT

 

XN12AF/XN20AF/

 

XN24AF/XN4A/XN5A

 

SN30AF/SN36AF/

 

SN4A/SN5A

4

AUTO ACQ CORRE

 

5 SCAN

5

AUTO ACQ WEED

 

1 SCAN

6

[TT DETAIL DATA]

[TRACK PRESET]

1BACK

2GATE SIZE S/ M /L/LL

3FILTER RESPONSE 1/ 2 /3/4

4LOST COUNT

9 SCAN

5MAX SPEED

100KTS

6TRACKING MODE

1/2/3/4

7START TIME TGT VECT TIME /SCAN

50SEC

20 SCAN

*: Not on IMO radar

TT DATA OUTPUT

Set the output format from J619 port (sentence, bearing and baud rate) of tracked targets.

Sentence:

(OFF: No output, TTM: Tracked target information, TTD: Tracked target data)

Bearing:

REL: Target bearing from own ship, degree relative,

 

Target course, degree relative.

 

TRUE: Target bearing, degree true, target course, degree true.

Baud rate:

(4800, 9600, 19200 or 38400 bps)

NOTE: The TT DATA OUTPUT port changes according to the setting for INS as described

on page 3-15.

 

INS-OFF:

Output from J619 port only

INS-SERIAL:

Output from J619 and J620 (TTM only) ports

INS-LAN:

Output from J619 and NETWORK (TTM only) ports

MAX RANGE

Choose the ARPA tracking range, 24 or 32 nm.

ECHO LEVEL

Set the detection level of echoes. The setting range is 1 to 31.

QV DISPLAY

OFF: Normal picture

ON: Quantized picture; always off at power on

3-13

Page 53
Image 53
Furuno 2837S, 2137S-BB installation manual TT Preset menu setting, TT Data Output