2. WIRING
Cover of PWR board
Fuse
PWR board
Upper part of processor unit (SPU assembly omitted)
J105 | J106 |
PWR board | J104 |
| J103 |
R21 |
|
(OVER) |
|
P108/J108 | J101 |
| |
8 7 6 5 4 3 2 1 |
|
Jumper connector |
|
(VH8P) |
|
(P)HV
AC FIL
How to adjust the overvoltage detection circuit:
1.Add or remove the jumper connector P108 and change the fuse.
2.Rotate R21 fully clockwise on the PWR board.
3.Connect a variable transformer between ship's mains and the input power terminal board
4.Adjust the variable transformer output (i.e., input voltage to the processor unit) as follows. For 100 VAC set: 144 VAC
For 220 VAC set: 288 VAC
5.Turn on the radar and rotate the R21 counterclockwise gradually until the overvoltage detection circuit functions (i.e., power supply cuts off).
6.Lower the output voltage of the variable transformer and confirm that the radar automatically turn on with a voltage lower than 142VAC or 284VAC.
7.Gradually increase the output voltage of the variable transformer and confirm that the overvoltage detection circuit functions at 144V or 288VAC of the variable transformer output.
8.Assemble and connect the processor unit.