Furuno 2137S-BB, 2837S installation manual How to adjust the overvoltage detection circuit

Models: 2137S-BB 2837S 2137S

1 123
Download 123 pages 8.3 Kb
Page 39
Image 39

2. WIRING

Cover of PWR board

Fuse

PWR board

Upper part of processor unit (SPU assembly omitted)

J105

J106

PWR board

J104

 

J103

R21

 

(OVER)

 

P108/J108

J101

 

8 7 6 5 4 3 2 1

 

Jumper connector

 

(VH8P)

 

(P)HV

AC FIL

How to adjust the overvoltage detection circuit:

1.Add or remove the jumper connector P108 and change the fuse.

2.Rotate R21 fully clockwise on the PWR board.

3.Connect a variable transformer between ship's mains and the input power terminal board TB-1 of the processor unit.

4.Adjust the variable transformer output (i.e., input voltage to the processor unit) as follows. For 100 VAC set: 144 VAC

For 220 VAC set: 288 VAC

5.Turn on the radar and rotate the R21 counterclockwise gradually until the overvoltage detection circuit functions (i.e., power supply cuts off).

6.Lower the output voltage of the variable transformer and confirm that the radar automatically turn on with a voltage lower than 142VAC or 284VAC.

7.Gradually increase the output voltage of the variable transformer and confirm that the overvoltage detection circuit functions at 144V or 288VAC of the variable transformer output.

8.Assemble and connect the processor unit.

2-13

Page 39
Image 39
Furuno 2137S-BB, 2837S installation manual How to adjust the overvoltage detection circuit